User manual

Configuring and Monitoring Through the LCD
4-14 Campus-RS Fractional Interface Card User Manual
CONFIGURING AS A MASTER OR SLAVE UNIT
The Transceiver Mode option determines the hierarchy of the two Campus
units when attempting to establish an HDSL link. There are three settings:
If a unit is set to Master, it initiates the HDSL link. The other Campus
unit must be set to Slave or Auto.
If a unit is set to Slave, it waits for the other Campus unit to initiate the
HDSL link. The other unit must be set to Master or Auto.
If a unit is set to Auto, it automatically switches between Master and
Slave until an HDSL link is established. The setting of the other Campus
unit is irrelevant. This is the default setting.
To change the Transceiver Mode:
1 Press Escape until CAMPUS RS I/F: FRAC displays.
2 Press Next until HDSL LINK CONFIG & STATUS displays, then press
Enter. OPERATING MODE displays.
3 Press Next. XCVR MODE displays, then press Enter.
4 Press Next to scroll through the Transceiver Mode options until the
desired setting displays.
5 Press Enter to select the displayed setting. XCVR MODE and the new
setting display.
Unless you have a compelling reason for doing otherwise,
ADC recommends leaving the Transceiver Mode option set to
Auto.