User manual
Configuring and Monitoring Through the LCD
4-18 Campus-RS Fractional Interface Card User Manual
Local Alarms
Loss of Signal (LOS) alarms can occur on the local unit. This section
describes how to view and configure this alarm.
Viewing Current Alarms
If the CURRENT ALARMS display indicates a local alarm, you can determine
the alarm type:
1 From the CURRENT ALARMS display, press Next twice.
LOCAL I/F ALARMS displays.
2 Press Enter. The current status of the local alarm displays.
Configuring the Alarm
There are two settings for the local Loss of Signal alarm:
• ENABLE enables the alarm
• DISABLE disables the alarm
To configure the local Loss of Signal alarm:
1 From the CURRENT ALARMS display, press Next until
LOCAL I/F ALARMS displays, then press Enter. The current status of
the local alarm displays.
2 Press Next until LOC LOSS OF SIG displays.
3 Press Enter.
4 Press Next to scroll through the settings for the alarm.
5 Press Enter to select the desired setting. LOC LOSS OF SIG displays.