Configuring with an ASCII Terminal
5-8 Campus-RS Fractional Interface Card User Manual
2 Type then press . The System Parameters menu displays.
3 Type then press .
The system restores the configuration options to their default values and
returns to the System Status menu.
The HDSL options must be the same for both the local and
remote unit. Resetting the Campus unit configuration values
on one unit only, may cause the HDSL link to go down.
1 ENTER
July 01, 2002 PAIRGAIN TECHNOLOGIES, CAMPUS RS, Version 4.3K 00:07:59
Local Unit ID: Campus V.35 Unit #19 Local I/F: FRAC V.35
Remote Unit ID: Campus V.35 Unit #27 Remote I/F: FRAC V.35
Circuit ID: Network #13
SYSTEM PARAMETERS
1) Change System Time
2) Change System Date
3) Change Unit ID
4) Change Circuit ID
5) Change Password
6) HDSL ES Alarm Threshold: Disabled (Disabled, 17, 170)
7) HDSL Margin Alarm Threshold: Disabled
8) Local Data Port LOS Alarm: Disabled (Disabled, Enabled)
9) Remote Data Port LOS Alarm: Disabled (Disabled, Enabled)
10) RESET TO FACTORY DEFAULT
(R)eturn (M)ain Menu
ENTER CHOICE>
1 0 ENTER