The remainder of this section describes how to set the Data Port options.
Setting the Data Rate
The data rate determines the speed at which data passes through the data port.
There are two steps to setting the data rate:
setting the rate multiplier
choosing from the list of available data rates, determined by the rate
multiplier and the HDSL Rate
July 01, 2002 PAIRGAIN TECHNOLOGIES, CAMPUS RS, Version 4.3K 00:33:29
Local Unit ID: Local I/F: FRAC V.35
Remote Unit ID: Inactive Remote I/F: Inactive
Circuit ID:
DATA PORT CONFIGURATION
1) Data Rate: 224 Kbps
2) Rate Multiplier: 56K (64K, 56K)
3) Timing Source: Internal (Port, Int, HDSL)
4) Transmit Clock: External (External, Internal)
5) Invert Input Clock: Off (Off, On)
6) Invert Output TX Clock: Off (Off, On)
7) Invert Output RX Clock: Off (Off, On)
8) Invert Data: Off (On, Off)
9) CTS: STD (STD, On, Off)
10) DSR: STD (STD, On, Off)
11) RLSD: Off (STD, On, Off)
12) LT: STD (STD, On, Off)
13) V.54 Loopbacks: Disabled (Disabled, Enabled)
(R)eturn (M)ain Menu
ENTER CHOICE>