User manual
Configuring with an ASCII Terminal
Campus-RS Fractional Interface Card User Manual 5-21
CONFIGURING AS A MASTER OR SLAVE UNIT
The Transceiver Mode option determines the hierarchy of the two Campus
units when attempting to establish an HDSL link. There are three settings:
• If a unit is set to Master, it initiates the HDSL link. The other Campus
unit must be set to Slave or Auto.
• If a unit is set to Slave, it waits for the other Campus unit to initiate the
HDSL link. The other unit must be set to Master or Auto.
• If a unit is set to Auto, it automatically switches between Master and
Slave until an HDSL link is established. The setting of the other Campus
unit is irrelevant. This is the default setting.
To change the Transceiver Mode:
1 From the Main Menu, type then press . The System Settings
Menu displays.
Unless you have a compelling reason for doing otherwise,
ADC recommends leaving the Transceiver Mode option set to
Auto.
3 ENTER
July 01, 2002 PAIRGAIN TECHNOLOGIES, CAMPUS RS, Version 4.3K 00:07:28
Local Unit ID:Campus V.35 Unit #19 Local I/F: FRAC V.35
Remote Unit ID:Campus V.35 Unit #27 Remote I/F: FRAC V.35
Circuit ID:Network #13
SYSTEM SETTINGS MENU
1) SYSTEM PARAMETERS
2) HDSL PARAMETERS
(R)eturn
ENTER CHOICE>