User manual
View Information and Status
Campus-RS Fractional Interface Card User Manual 6-3
The Current System Status menu provides the following information:
• Local Alarms indicates the current local alarm status
• Remote Alarms indicates the current remote alarm status
• Loopback indicates the current loopback status
• Margin (db) indicates the minimum (mn), current (cr), and maximum
(mx) HDSL margin value, measured in dB, relative to the signal-to-noise
ratio required for a Bit Error Rate (BER) of 10
-7
• Pulse Attn (db) indicates the decrease in amplitude of the transmitted
signal as measured at the HDSL receiver
• 24 Hour ES indicates the number of errored seconds over the last
24 hours
• 24 Hour UAS indicates the number of unavailable seconds over the last
24 hours
• Last Cleared indicates the date and time when the error counter was last
cleared
July 01, 2002 PAIRGAIN TECHNOLOGIES, CAMPUS RS, Version 4.3K 00:05:30
Local Unit ID: Campus V.35 Unit #19 Local I/F: FRAC V.35
Remote Unit ID: Campus V.35 Unit #27 Remote I/F: FRAC V.35
Circuit ID: Network #13
CURRENT SYSTEM STATUS
Local Alarms: HDSL-A, HDSL-B
Remote Alarms:
Loopback:
HDSL-A HDSL-B
LOCAL REMOTE LOCAL REMOTE
-------- -------- -------- --------
mn/cr/mx mn/cr/mx mn/cr/mx mn/cr/mx
Margin (dB): na/na/na na/na/na na/na/na na/na/na
Pulse Attn (dB): 00 00 00 00
24 Hour ES: 00000 00000 00000 00000
24 Hour UAS: 02745 00000 02745 00000
Last Cleared: None
--------------------------------------------------------------------------------
(U)pdate (C)lear
(R)eturn (M)ain Menu