User manual

View Information and Status
Campus-RS Fractional Interface Card User Manual 6-3
The Current System Status menu provides the following information:
Local Alarms indicates the current local alarm status
Remote Alarms indicates the current remote alarm status
Loopback indicates the current loopback status
Margin (db) indicates the minimum (mn), current (cr), and maximum
(mx) HDSL margin value, measured in dB, relative to the signal-to-noise
ratio required for a Bit Error Rate (BER) of 10
-7
Pulse Attn (db) indicates the decrease in amplitude of the transmitted
signal as measured at the HDSL receiver
24 Hour ES indicates the number of errored seconds over the last
24 hours
24 Hour UAS indicates the number of unavailable seconds over the last
24 hours
Last Cleared indicates the date and time when the error counter was last
cleared
July 01, 2002 PAIRGAIN TECHNOLOGIES, CAMPUS RS, Version 4.3K 00:05:30
Local Unit ID: Campus V.35 Unit #19 Local I/F: FRAC V.35
Remote Unit ID: Campus V.35 Unit #27 Remote I/F: FRAC V.35
Circuit ID: Network #13
CURRENT SYSTEM STATUS
Local Alarms: HDSL-A, HDSL-B
Remote Alarms:
Loopback:
HDSL-A HDSL-B
LOCAL REMOTE LOCAL REMOTE
-------- -------- -------- --------
mn/cr/mx mn/cr/mx mn/cr/mx mn/cr/mx
Margin (dB): na/na/na na/na/na na/na/na na/na/na
Pulse Attn (dB): 00 00 00 00
24 Hour ES: 00000 00000 00000 00000
24 Hour UAS: 02745 00000 02745 00000
Last Cleared: None
--------------------------------------------------------------------------------
(U)pdate (C)lear
(R)eturn (M)ain Menu
ENTER CHOICE>