GFA-6002 & GFA-6006 Custom Install Power Amplifiers ch 1 < on / standb y distorti on alert > therma l protect ion > ch 2 ch 3 ch 4 ch 5 ch 6 G F A 60 06 ADCOM GFA-6006/02 Owner’s Manual | 1
WELCOME Dear Fellow ADCOM Product Owner, Welcome to the ADCOM family! For more than twenty years, ADCOM products have delivered excellent performance and value for customers around the world. Our products are designed by our experienced and demanding engineering team, built to the highest standards in our factory, and sold and serviced through dealers, custom installers, and other retailers whose primary goal is your complete satisfaction.
TABLE OF CONTENTS Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Table of Contents . . . . . . . . . . . . . . . . . . . . . . 3 Precautions and Warnings . . . . . . . . . . . . . . . 4 Unpacking Your Amplifier . . . . . . . . . . . . . . . 5 Safety Information . . . . . . . . . . . . . . . . . . . . . 5 Description & Features . . . . . . . . . . . . . . . . . 6 Installing & Connecting . . . . . . . . . . . . . . . . . 7 Description of Front Panel . . . . . . . . . . . . . .
N OCK THE FOLLOWING PRECAUTIONS AND SAFETY INSTRUCTIONS ARE REQUIREMENTS OF UL AND CSA SAFETY REGULATIONS Warning: To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture.
Unpacking the Amplifier Before your new ADCOM amplifier left our factory, it was carefully inspected for physical imperfections and tested for all electrical parameters as a routine part of ADCOM’s systematic quality control. This, along with full operational and mechanical testing, should ensure a product flawless in both appearance and performance. After you have unpacked the GFA6002/06, inspect it for physical damage.
Description of Unit GFA-6006 Features Congratulations on your decision to purchase the GFA-6002 or • Precision-matched devices used throughout the signal path GFA-6006 custom installation power amplifier. The GFA-6002 and GFA-6006 have been designed to be musically accurate in a configuration specifically designed to integrate with any home audio pre-amplifier. You have made a wise choice that will reward you for years to come with exceptionally accurate and musical sound reproduction.
Installing the GFA-6002 and GFA-6006 During normal home operation the internal heatsinks of the GFA-6002/ 6006 may become warm. However, there are instances during high-level playback into low impedances when the heatsinks will become much warmer than usual. To ensure the amplifier’s long-term, trouble-free operation it is necessary to provide adequate ventilation for the heatsinks. Therefore, the GFA-6002/6006 should be kept away from external sources of heat such as radiators and hot-air ducts.
Description of Unit: Front Panel [1] On/Standby/Vacation This LED monitors the status of operation of the amplifier. The LED will glow amber whenever the rear panel Power/ Vacation switch is in the OFF (powered down with only minimal circuitry energized) or AUTO position (amplifier is in the standby mode).
GFA-6006 Rear Panel 8 4 GFA-6002 Rear Panel 5 Description of Unit: Rear Panel [4] Inputs & [5] Outputs The audio inputs and outputs for the GFA-6002 and GFA-6006 are through high-quality, gold-plated RCA jacks to minimize high-frequency losses, noise, etc. They will accept standard RCA-type plugs, one for each of the channels. To insure that the performance designed into the amplifier is preserved, you should use the highest quality audio cables possible.
and labeled “+,” and the negative is color coded BLACK and labeled “-”. The positive terminal on the speaker will be color coded RED, or will be labeled “+,” “pos,” “positive,” “8 ohms,” or “4 ohms.” The negative terminal on the speaker will be color coded BLACK, or will be labeled “-,” “neg,” negative,” “C,” “Common,” “G,” or “ground.” Note: Bridged operation requires different loudspeaker connections. For details see the section Bridged Operation.
The proper fuse values are: GFA-6002 for 120 volt operation Fuse Rating: 5 Amp 250 Volt Buss®: AGC-5/250V Littlefuse®:(3AG) 312005/250V GFA-6002 for 230 volt operation Fuse Rating: 3 Amp 250 Volt Buss®: AGC-3/250V Littlefuse®:(3AG) 312003/250V GFA-6006 for 120 volt operation Fuse Rating: 12 Amp 250 Volt Buss®: AGC-12/250V Littlefuse®:(3AG) 3120012/250V GFA-6006 for 230 volt operation Fuse Rating: 6 Amp 250 Volt Buss®: AGC-6/250V Littlefuse®:(3AG) 312006/250V Before attempting to replace a failed fuse, be ce
SYMPTOM POSSIBLE REASON POSSIBLE SOLUTION Power LED does not AC Power Cord(s) not plugged in. Plug in AC Power Cord(s). glow. No sound AC Fuse(s) failed. Transformer thermal protection engaged. I2V DC triggering malfunctioning. Replace AC Fuse(s). Wait until unit cools down. It will reset. Reset power switch manually. Check connection of 12V DC trigger at source. Power LED glows, but no sound Preamp or source unit is not on. Connections in rear of amp are loose. Make sure whole system is on.
be helpful if you indicate which major city is accessible to your home. Please address mail inquires to: ADCOM Service 8541 East Anderson Drive Scottsdale, Arizona 85255 USA Phone, Fax or Email inquires to: Voice: (480) 607-2277 or Fax: (480) 348-9876 Monday through Friday, 8:00 AM to 4:00 PM MST Email: service@adcom.com For fax inquires, please include a return fax number for the reply.
GFA-6002 Specifications Power Rating (To IEC/CEA-490A Requirements) 70 Watts continuous average power into 8 ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 1.0% THD. 100 Watts continuous average power into 4 ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 1.0% THD. Bridged Power: 175 Watts continuous average power (one channel) into 8 ohms at any frequency between 20Hz and 20kHz with at less than 1.0% THD.
GFA-6006 Specifications Power Rating (To IEC/CEA-490A Requirements) 70 Watts continuous average power into 8 ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 1.0% THD. 100 Watts continuous average power into 4 ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 1.0% THD. Bridged Power: 175 Watts continuous average power (one channel) into 8 ohms at any frequency between 20Hz and 20kHz with at less than 1.0% THD.
ADCOM A division of Klein Technology Group, LLC 8541 East Anderson Drive Scottsdale, Arizona 85255 Voice: (480) 607-2277 Fax: (480) 348-9876 http://www.adcom.