AdderLink Infinity { User Guide ALIF1000 ALIF2000
Front panel indicators................................................................22 Further information Getting assistance.......................................................................23 Appendix.....................................................................................24 RS232 ‘null-modem’ cable pin-out........................................24 Supported video modes........................................................24 ALIF 1000 general specifications..........................
One-to-many configuration Using multicast techniques, an unlimited number of receivers* can receive video and audio data streams from a single TX unit. ALIF RX Gigabit Ethernet ALIF RX * A maximum of twelve concurrent USB inputs (via multiple RX units) are permitted to a single TX unit. ALIF RX ALIF TX Mixing ALIF1000 and ALIF2000 units It is possible to mix ALIF1000 and ALIF2000 transmitters and receivers. The only exception is that the ALIF1000 units do not support dual link DVI video signals.
AdderLink ALIF1000T and ALIF1000R unit features The ALIF1000 units are housed within durable, metallic enclosures with most connectors situated at the rear panel only the Ethernet ports are situated at the front panel. The smart front faces feature the operation indicators. ALIF1000R (receiver) - front TRANSMIT RECEIVER AdderLink AdderLink www.adder.com www.adder.com NET SER AUD USB DVI PWR • NET On when valid network link is present. Flashes when the unit is in error.
AdderLink ALIF2000T and ALIF2000R unit features The ALIF2000 units are housed within durable, metallic enclosures with most connectors situated at the rear panel only the Ethernet and fibre ports are situated at the front panel. The smart front faces feature the operation indicators.
What’s in the box (ALIF1000) ALIF1000T package CD-ROM NET SE R AU D USB DV I PW R TR AN SM IT ALIF1000T unit Combined DVI-D and USB cable (1.8m) ww w.ad de r.com Four self-adhesive rubber feet ALIF1000 Quick Start Guide Serial null modem cable 2m 2 x Audio cable 2m (3.5mm stereo jacks) Lin k Ad der Power adapter (12.5W) and country-specific power lead ALIF1000R package Power adapter (12.
What’s in the box (ALIF2000) ALIF2000T package CD-ROM NET SE R AU D USB DV I PW R TR AN SM Combined dual link DVI-D and USB cable (1.8m) IT ww w.ad de r.com ALIF2000T unit Four self-adhesive rubber feet ALIF2000 Quick Start Guide Serial null modem cable 2m 2 x Audio cable 2m (3.
Fibre module (for ALIF2000) Part number: SFP-MM-LC Single link DVI-D to DVI-D video cable Part number: VSCD1 Combined dual link DVI-D and USB (USB type A to B) cable Part numbers: VSCD3 (1.8m length) VSCD4 (5m length) Power adapter (12.5W) and country-specific power lead for ALIF1000 units Part number: PSU-IEC-5VDC-2.
Installation Mounting Connections Rack brackets The optional brackets (plus four screws), allow the units to be secured within a standard rack slot. Note: The ALIF units and their power supplies generate heat when in operation and will become warm to the touch. Do not enclose them or place them in locations where air cannot circulate to cool the equipment. Do not operate the equipment in ambient temperatures exceeding 40oC.
Connections CABLE LINK page 14 SERIAL LINK page 12 ALIF TX OR ALIF RX FIBRE LINK (ALIF2000 only) page 14 POWER IN page 13 POWER IN page 18 USB DEVICES page 17 SERIAL LINK page 17 Click a connection to see details USB LINK page 12 MIC & SPEAKERS page 16 VIDEO LINK page 15 AUDIO LINKS page 11 VIDEO LINK page 10 Installation involves linking the ALIF TX unit to various ports on the host computer, while the ALIF RX unit is atta
To make a video link 1 Wherever possible, ensure that power is disconnected from the ALIF and the host computer.
TX audio links VIDEO LINK The ALIF units support two way stereo digital sound so that you can use a remote microphone as well as speakers. AUDIO LINKS LINK ALIF RX POWER IN [ALIF1000] LIN 1 Connect an audio link cable between the IN socket on the TX unit rear panel and the speaker output socket of the host computer.
USB LINK To make a USB link 1 Connect the type B connector of the supplied USB cable to the USB port on the TX unit rear panel. SERIAL LINK ALIF TX LINK ALIF RX TIO NS 1 AUDIO LINKS USB LINK SERIAL LINK POWER IN OP 1 The AUX port is an RS232 serial port that allows extension of RS232 signals up to a baud rate of 115200. The port has software flow control, but no hardware flow control. ALIF TX LINK ALIF RX POWER IN To connect the AUX port 1 Ensure that power is removed from the ALIF unit.
LINK ALIF RX POWER IN To apply power in 1 Attach the output lead from the power adapter to the 5V socket on the rear panel of the unit. 2 Connect the IEC connector of the supplied country-specific power lead to the socket of the power adapter. IN US DOO EO R NL Y 1 2.5 A Due to the increased power requirements of the ALIF2000 series, these models are supplied with larger capacity (20W) power adapters. The standard 12.
To link ALIF units using Gigabit Ethernet 1 Connect a CAT 5, 5e, 6, or 7 cable to the socket on the front panel of the ALIF unit.
RX video display [ALIF2000 when using two single link DVI-D displays] Connect an additional video input from the secondary video port of the computer system using the supplied secondary DVI-D link cable. DV I- D-2 DV I- D-1 US ER CO NS OL MIC & ALIF units support DVI digital ALIF TX SPEAKERS video signals and so use DVI-D video connectors throughout.
ALIF RX POWER IN USB DEVICES LINK LINK MIC & SPEAKERS SERIAL LINK To connect a microphone (or line in) and/or speakers 1 Connect the lead from a mono microphone or, alternatively, a line in connection from an audio device to the 3.5mm socket labelled LINE IN/MIC IN on the rear panel. 2 Connect the lead from stereo speakers or, alternatively, a line out connection from an audio device to the 3.5mm socket labelled LINE OUT on the rear panel.
LINK POWER IN To connect the AUX port 1 Ensure that power is removed from the ALIF unit. 2 Connect a suitable serial ‘null-modem’ cable (see Appendix for pin-out) between the AUX port on the right hand side of the ALIF rear panel and your remote serial device. LIN EO UT AU X LIN E MI I CI ER CO NS OL Serial (null-modem) link from your computer E Connection from USB device Supported USB Devices USB devices are supported using True Emulation technology.
ALIF RX LINK POWER IN MIC & SPEAKERS USB DEVICES SERIAL LINK To apply power in 1 Attach the output lead from the power adapter to the 5V socket on the rear panel of the unit. 2 Connect the IEC connector of the supplied country-specific power lead to the socket of the power adapter. A 20W model (for ALIF2000) Model: SA06-xxxxx-V Input: 100-240V Output: 5V 2.5A (12.5W Max.) Model: SA06-xxxxx-V Input: 100-240V Output: 5V 4A (20W Max.
Configuration To perform a manual factory reset 1 Remove power from the ALIF unit. 2 Use a narrow implement (e.g. a straightened-out paper clip) press and hold the recessed reset button on the front panel. Power on the unit and then release the reset switch. Ad der Lin k Configuring network switches to ensure efficient operation With IP Multicast there is a risk that network segments can get saturated with data that are not destined for any device on that segment.
ww w.a d [ALIF2000] Note: Use the right hand Ethernet port. der .co m 2 Connect the other end of the link cable to your network. 3 Similarly, link your computer to the same network. Note: A Gigabit connection is not essential for configuration purposes. 4 If not already switched on, power up your computer and the ALIF unit. You are now ready to use the browser-based configuration utility.
Finding the latest upgrade files Firmware files for the ALIF units are available from the Technical Support > Updates section of the Adder Technology website (www.adder.com). To upgrade a single unit via network link 1 Download the latest upgrade file from the Adder Technology website. Note: There are separate upgrade files for TX and RX units.
The six front panel indicators on each unit provide a useful guide to operation: NET SER AUD USB DVI PWR Indicators These six indicators clearly show the key aspects of operation: • NET On when valid network link is present. Flashes when the unit is in error. Front panel indicators In operation, many ALIF installations require no intervention once configured. The TX and RX units take care of all connection control behind the scenes so that you can continue to work unhindered.
Further information in the UK: in the US: 01954 780081 +1 888 275 1117 • Phone in the UK: in the US: 01954 780044 +1 888 932 3337 • Fax • Email – support@adder.com • Adder Technology website – www.adder.com Check the Support section of our website for the latest solutions and driver files.
Appendix RS232 ‘null-modem’ cable pin-out RXD TXD 3 3 TXD DTR 4 4 DTR DSR 6 6 DSR DCD 1 1 DCD GND 5 5 GND RTS 7 7 RTS CTS 8 8 CTS Supported video modes ALIF units support all VESA and CEA video modes. ALIF 2000 general specifications Casing (w x h x d): Construction: Weight: Mount kits: Power to adapter: Power to unit: Operating temp: Approvals: 198mm (7.92”) x 44mm (1.76”) x 120mm (4.8”) 1U compact case, robust metal design 1.11kg (2.
• • • • For use in dry, oil free indoor environments only. Warning - live parts contained within power adapter. No user serviceable parts within power adapter - do not dismantle. Plug the power adapter into a socket outlet close to the module that it is powering. Replace the power adapter with a manufacturer approved type only. Do not use the power adapter if the power adapter case becomes damaged, cracked or broken or if you suspect that it is not operating properly.
Canadian Department of Communications RFI statement This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le règlement sur le brouillage radioélectriques publié par le ministère des Communications du Canada.
Adder Technology (Asia Pacific) Pty Ltd 8 Burn Road #04-10, Trivex 369977 Singapore Tel +65 6288 5767 Fax +65 9616 1283 Adder Corporation, 350R Merrimac Street, Newburyport, MA 01950, United States of America Tel: +1-888-932-3337 Fax: +1-888-275-1117 Adder Technology Limited, Unit 5, Saxon Way, Bar Hill, Cambridge, CB23 8SL, United Kingdom Tel: +44 (0)1954 780044 Fax: +44 (0)1954 780081 © 2011 Adder Technology Limited All trademarks are ac
R Assistance 23 Dimensions 24 B F Bracket rack mount 8 Brackets fitting 8 Browser-based utility 20 Factory reset 19 Firmware upgrade 21 Front panel 3 Front panel indicators 22 Rack mounting 8 Rear panel 3 Reset manual 19 C G Safety information 25 Specifications 24 Switch IGMP configuration 19 Cable spec null modem 24 Configuration browser-based utility 20 styles 2 Connections network link 14 overview 9 RX audio 16 RX AUX port 17 RX power in 18 RX USB devices 17 RX video displ