Specifications
SATA-IO Confidential  49   
2.12.  Phy General Requirements 
2.12.1.  PHY-01 : Unit Interval 
2.12.1.1. Device/Host Expected Behavior 
See section 7.2.2.1.3 of Serial ATA Revision 2.6. 
•  See section 7.4.11 of Serial ATA Revision 2.6. 
Measurement Requirements 
•  For products which support 3Gb/s, this requirement must be tested at both interface rates (1.5Gb/s and 
3Gb/s). 
•  PHY-01a - Mean Unit Interval measured between 666.4333ps (min) to 670.2333ps (max) (for products 
running at 1.5Gb/s) 
Pass/Fail Criteria 
•  PHY-01b - Mean Unit Interval measured between 333.2167ps (min) to 335.1167ps (max) (for products 
running at 3Gb/s) 
•  The values above shall be based on at least 100,000 UIs (covers at least one SSC profile) 
2.12.2.  PHY-02 : Frequency Long Term Stability 
2.12.2.1. Device/Host Expected Behavior 
This test is not applicable to products that support SSC.  
See section 7.2.2.1.4 of Serial ATA Revision 2.6. 
•  See section 7.4.6 of Serial ATA Revision 2.6. 
Measurement Requirements 
•  This test is only run once at the maximum interface rate of the product (1.5Gb/s or 3Gb/s). 
•  The execution of this test must include use of the low pass filter defined within section 7.4.11 of Serial ATA 
Revision 2.6. 
•  f
tol
 measured between -350ppm and 350ppm 
Pass/Fail Criteria 
2.12.3.  PHY-03 : Spread-Spectrum Modulation Frequency 
2.12.3.1. Device/Host Expected Behavior 
See sections 7.2.2.1.5 and 7.3.3 of Serial ATA Revision 2.6. 
This test requires support for Spread Spectrum Clocking (SSC), which is optional. 
•  See section 7.4.11 of Serial ATA Revision 2.6. 
Measurement Requirements 
•  This test is only run once at the maximum interface rate of the product (1.5Gb/s or 3Gb/s). 
•  f
SSC
 measured between 30kHz and 33kHz 
Pass/Fail Criteria 
•  The value above shall be based on a mean of at least 10 complete SSC cycles 