User`s manual

DIGITAL-LOGIC AG MPC40/A/B/C, MPC41 Manual V1.4C
98
9.11.1.4 Submenu „Security“
To use password security functions see following chart:
Feature Options Description
Setting of
user pass-
word
Max. 7 alpa-
numeric fig-
ures
Pressing the <Enter> key summons the entering of a
user password. Therewith certain settings are protected.
Feature Options Description
Setting of
supervisor
password
Max. 7 al-
phanumeric
figures
Pressing the <Enter> key summons the entering of a
supervisor password. This function allows full access to
all settings.
Password on
boot
Enabled
Disabled
Setting „Enabled“ summons the entering of a password
for boot function from floppy.
9.11.1.5 List of Supported USB Devices
Excerpt of devices tested by Digital-Logic:
Devices Manufacture Boot Results
USB Floppies TEAC Model FD-05PUB
OK
USB Keyboards Logitech, iTouch
CHICONY, KU8933
OK
USB Mice Logitech, Mini Wheel Mouse M-BE55
OK
USB CD-
R-WRITERS
IOMEGA Predator USB 4x4x6 EU
Acer CRW 6424MU
OK
USB CD- ROMS FREECOM FC-CD40
Failed
USB CD-
R-WRITERS
HP CD-Writer 8230e
Failed
USB 2.0 CD-R-Writers Teac DW-224PUK
OK
USB-CD TEAC-210
OK
USB memory stick ASUS BlackPerl 32MB
OK
USB 2.0 memory stick SanDisk cruzer mini (128MB – 1GB)
SanDisk Micro (Misc size)
SwissBit 128MB
OK
OK
OK