User guide

169 | P a g e
cannot say. We do know that it works with the H89 Magnolia Microsystems 77320 SASI/SERIAL
card.
In the abovementioned configuration, both units may have different sized Winchesters, but the
internals of the cabinet are identical, i.e., they each have a Xebec controller card. Thus for this
method, you simply remove the cabinet of the second, or slave unit, and remove the "0" jumper
block from J5 and set it to "1". This will select that unit as the second unit. The main cabinet
already has this set for "U" for the first unit. In addition, the second unit should have the
resistor pack installed at 6F (Note: location may differ on different Xebec revisions, however, the
item you are looking for is the only 14 pin type of IC (it is actually a resistor pack) in an
Integrated Circuit socket). This must be removed from the master unit and installed in the slave
unit. If you purchased the unit from QUIKDATA, the second unit will already be properly
configured. You still must remove the cover from the first drive unit, or master unit, and remove the
14 pin IC resistor pack. Store it away for future use, perhaps taped to the floor or wall of the
unit's cabinet.