User manual
Fault/Remedy
27
Body Analyser Scales BA 1300-1304
English
English
Fault/Remedy
Fault Possible Cause
No function Battery empty or inserted the wrong way
around?
The scales appear to be displaying
false weighing results
Are the scales standing on a rm, even
surface?
Is a device that can cause electromagnetic
disturbances located in the vicinity of the
scales?
Remove the battery from the scales and
wait a moment. Reinsert the battery. The
data stored up to this point will be retained.
“Err” is shown on the display The maximum capacity of the scales
(180kg) has been exceeded.
“Lo” is shown on the display The battery is empty (see “Changing the
battery”).
“ErrL” is shown on the display The fat proportion % is too low: Below 4%
nothing can be displayed
“ErrH” is shown on the display The fat proportion % is too high: Above
60% nothing can be displayed.
“C” is shown on the display The weighing/measurement process was
faulty: The scales are not standing stably or
you are not standing still on the weighing
surface during weighing.