Specifications

7.
8.
9.
Eon0 4 Tup+ Selection
As shipped, zone 4 Is configured as a standard burglary zone. )t>wever,
it can also be configured in PROM as either a fully supervised Fire
Zone or a 24 hour day burglary zone (during disarmed period, a trouble
indication is communicated and audibly sounded if the loop is opened
or shorted; a burglary alarm is triggered if the loop is opened or
shorted during armed period).
Zane 5 and 6 Options
As shipped, zone 5 is configured as a silent panic zone, zone 6 as
a burglary zone.
Optionally, zone 5 and/or 6 may be configured in
PROM as audible panic zones.
In addition, if zone 5 is set up as
a Silent Panic Zone, console display of both the panic condition
as well as the activity of the cormlunicator may be inhibited. (For
example, if zone 5 is set up as a silent medical emergency zone,
the user would want an indication that the alarm has been triggered,
however,
if the zone 5 is intended for hold-up use, the display would
not be desirable).
~scellamems PRol Selatablc
Control
Options
Alternate Siren somds:
As shipped, the system will give the following sounds: Steady
rapid two-tone (Electronic bell) for Burglary/Panic; interrupted
rapid two-tone for fire. Optionally, steady slow two-tone for
Burglary/Panic may be PROM selected.
b)
Alarm Sounder .Dlng' Conflrution
of klimg:
When PROM selected, this option will cause a l/2 second "Ding'
of the exterior bell and/or siren at the end of the arming sequence.
If the communicator has been set
up
to send opening and closing
reports, the "Ding" will occur when the camnunicator has received
a kissoff on a closing report.
If opening/closing reports are
not used, the "Ding" will occur when the exit delay period has
expired.
d
Arming status RPluity:
The system has an output at
TBI-1
that may be used to indicate
the arm/disarm status of the system to other devices (for exmple,
space protection).
As shipped, the system will give the following
output:
+12 volts Aen armed
0 volts when disarmed
Optionally, the polarity can be PROM be reversed to give:
0 volts when disarmed
suitable for Ademco 12 volt and
AC powered
628-5