Entering and Exiting Programming Mode
Enter Programming mode using either method a or b:
a. Press both the [] and [#] keys at the same time
within 30 seconds after power is applied to the
control.
b. Enter the Installer Code + [8] + [0] keys.
Exit the Programming mode by either method a or b:
a. Press [] + [9] + [8]. Exiting by this method
prevents the Installer Code from being used to re-
enter Programming mode. Only entry method “a”
can be used to re-enter the Programming mode.
b. Press [] + [9] + [9]. Exiting by this method
permits the installer code to re-enter the
Programming mode.
NOTE:
The system sends Program Mode Entry and Program
Mode Exit report codes to the central station upon
entering and exiting the program mode.
Data Field Programming Mode
In the Programming Mode you may access any field
simply by entering either [] or [#] + the field number:
To write or change information in a field press []
+ the field number (27).
To read the information in a field press [#] + the
field number (#27).
When the entries for a field are completed, the keypad
beeps three times and advances to the next field.
NOTE: If the number of digits that you enter in a data
field is fewer than the maximum permitted (for
example, a phone number), the keypad displays the last
entry and waits. To proceed, enter [] + the next data
field you wish to program.