7RXFK 6FUHHQ .H\SDG ,QVWDOODWLRQ DQG 6HWXS *XLGH ARMED READY MESSAGE HOME FUNC PANIC BACK ® K0977 4/03 WWW.DIYALARMFORUM.
WWW.DIYALARMFORUM.
Table of Contents x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x SECTION 1 – General Information.............................................. 1–1 About the 6270 ................................................................................. 1–1 System Features .............................................................................. 1–1 Security......................................................................................... 1–1 Setup .......................................
How to Clean the 6270 .................................................................... 6–1 Routine Care .................................................................................... 6–3 SECTION 7 – Troubleshooting...................................................... 7–1 Troubleshooting ............................................................................... 7–1 Diagnostics ....................................................................................... 7–1 About Diagnostics .......
Conventions Used in This Manual x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Before you begin using this manual, it is important that you understand the meaning of the following symbols (icons) and text note. notes include specific information that must be followed if you are UL These installing this system for a UL Listed application.
vi WWW.DIYALARMFORUM.
S E C T I O N 1 General Information x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In This Section ♦ About the 6270 ♦ Compatibility ♦ System Features x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x About the 6270 The 6270 is an intuitive, graphical touch-screen keypad that combines security and home control.
6270 Installation and Setup Guide x x Diagnostics Keypad Emulation Compatibility The below listing identifies the alarm systems that the 6270 can interface with, the maximum number of 6270s that can be used with each system, and the minimum alarm panel software revision level for compatibility. ALARM SYSTEM VISTA-20PS VISTA-128BP VISTA-128FBP VISTA-250BP VISTA-250FBP FA168CPS FA1660C FA1700C MAXIMUM NUMBER OF 6270s 2 3 3 3 1 2 3 1 MINIMUM SOFTWARE REVISION LEVEL All Levels 2.4 1.6 2.4 1.5 All Levels 2.
S E C T I O N 2 Mounting and Wiring x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In This Section ♦ Mounting the 6270 ♦ Wiring the 6270 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Mounting the 6270 The 6270 should be mounted using the following criteria: x x The 6270 must be mounted indoors, and should be mounted at eye level for easy viewing by the user. To mount the 6270, see Figure 1 and complete the following steps: 1.
6270 Installation and Setup Guide MOUNTING SCREWS (4) (TYP) CASE FRONT D ARME Y READ WALL OR MOUNTING SURFACE AGE BACK MESS C PANI FUNC HOME CASE BACK 6270-003-V0 Figure 1. Mounting the 6270 Wiring the 6270 Connect 6270 in parallel with keypads and other peripheral devices using the keypad data (ECP) bus. To wire, see the Summary of Connections diagrams at the back of this guide, or the appropriate Systems Interconnection Diagram provided, and follow the instructions below.
SECTION 2: Mounting and Wiring Connect the wires to the 6270 terminal block as follows: 1. The 6270 has holding clips on the case back to hold the case front while you are wiring the unit. Hang the case front on the holding clips as shown in Figure 2. WALL OR MOUNTING SURFACE CASE BACK Y + G CASE FRONT 6270-009-V0 Figure 2. Wiring Preparation 2. Connect the + terminal of the supplementary power supply to terminal block position 2 (+12VDC terminal of the 6270 (red wire)). 2–3 WWW.DIYALARMFORUM.
6270 Installation and Setup Guide DATA OUT (YELLOW) +12VDC (RED) GROUND (BLACK) + + + + + + DATA IN (GREEN) Y + G 6270-002-V0 Figure 3. Wiring the 6270 3. Connect the AUX – terminal of the control panel to the (–) terminal of the supplementary power supply (black wire). 4. Connect the (–) terminal of the supplementary power supply to terminal block position 3 (GND terminal of the 6270 (black wire)). 5.
S E C T I O N 3 Front Panel LEDs and Buttons x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In This Section ♦ Front Panel LEDs ♦ Front Panel Buttons x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Front Panel LEDs ARMED READY MESSAGE HOME FUNC PANIC BACK 6270-001-V0 Front Panel LEDs and Buttons 3–1 WWW.DIYALARMFORUM.
6270 Installation and Setup Guide LED DESCRIPTION ARMED ON – Security system is armed. OFF – Security system is not armed. READY ON – Security system is disarmed and ready to arm. OFF – Security system is armed or disarmed but not ready. If disarmed, faults or troubles are present. MESSAGE FLASHING – The 6270 contains message(s) for the User OFF – No messages. Front Panel Buttons BUTTON DESCRIPTION HOME Used to return to the HOME screen display from any submenus. FUNC Reserved for future use.
S E C T I O N 4 Initial Setup x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In This Section ♦ Programming the Conrol Panel ♦ How to Access the Central Station Screen ♦ 6270 Initialization ♦ 6270 Setup ♦ How to Change the ECP Address ♦ Setting Chime Mode On/Off x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Programming the Control Panel The 6270 will not be fully operational unless its address in the control panel has been enabled for an alpha console, AUI type de
6270 Installation and Setup Guide 6270 Initialization Power Up When initially powered, the screen displays the boot sequence as it is performed. After it is determined what services are available, the screen displays the Set ECP Address screen. SCREEN ACTION If the system is incorporating only one 6270, leave the address set to 1 and press the OK button. The boot-up process will continue until completion.
SECTION 4: Initial Setup How to Access the Central Station Screen To Access the “Central Station” screen perform the following: 1. Press the SECURITY button on the “Home” screen. The “Arming” screen is displayed. SCREEN ACTION 2. Press the MORE CHOICES button. The “More Choices” screen is displayed. 3. Press the SETUP button on the “More Choices” screen. The “Setup” screen is displayed. 4. Press the ADVANCED SETUP button. The Enter Authorized Code: authorization screen is displayed. 4–3 WWW.
6270 Installation and Setup Guide SCREEN ACTION 5. Enter your 4-digit Installer code. The “Advanced Setup” menu screen is displayed. Note: If the top of the screen is displaying ECP Error, the ECP address in the 6270 is not valid for the panel that it is connected to. To change the ECP address in the 6270 when ECP Error is being displayed, enter the 6270 default code of “4140” to advance to the next screen. 6. Press the Central Station button. The “Central Station” menu screen is displayed. 4–4 WWW.
SECTION 4: Initial Setup To change the address, perform the following. SCREEN ACTION 1. On the “Central Station” screen press the ECP Address button. A pop-up window is displayed with options for selecting the 6270's ECP address. 2. The available ECP addresses are: 1-2 for residential controls or 1-30 for commercial controls Select the ECP address for this 6270 using the Up/Dn arrows. Press the OK button to accept the address setting or the CANCEL button to maintain the original ECP address.
6270 Installation and Setup Guide How to Select System Options The system options allow you to place buttons on the "Home" screen. The SECURITY and MESSAGES buttons are always displayed and cannot be removed. A Lighting button can also be added to the “Home” screen. To avoid confusion to the user, only buttons whose options are functional in the system should be displayed. To select the system options, do the following: SCREEN ACTION 1. On the “Central Station” screen press the Options button.
SECTION 4: Initial Setup How to Set the NIGHT Setup Button Function The NIGHT button can be set to arm the system in one of four arming modes: x x x x Away - When selected, arms all zones with entry delay. Stay - When selected, arms perimeter zones with entry delay. Instant - When selected, arms perimeter zones without entry delay. Maximum - When selected, arms all zones without entry delay. To set the NIGHT button function, do the following: SCREEN ACTION 1.
6270 Installation and Setup Guide SCREEN ACTION How to View and Edit Screen Security The Screen Security button displays a screen that lists the various screen classes in the 6270 and lists what level user has been given access to them. To view and/or edit screen security, do the following: SCREEN ACTION 1. On the “Central Station” screen, press the Screen Security button. A listing of the classes of screens and the user level that has access to them will be displayed. 2.
SECTION 4: Initial Setup SCREEN ACTION 3. Select the level of user who is to have access to the selected class of screens and then select the OK button. The Screen Security screen will be redisplayed listing the change. Depress the BACK button to return to the “Central Station” screen. How to View the Panel Configuration The Panel Config button displays a screen that contains the configuration of the panel that the 6270 is connected to. To view the panel configuration, do the following: SCREEN ACTION 1.
6270 Installation and Setup Guide SCREEN ACTION 3. Select OK to delete the configuration or Cancel to return to the “Panel Configuration” screen. If you select OK, the 6270 will be reset and the panel configuration will be downloaded from the panel into the 6270. After the reset and download is complete, the “Home” screen is displayed. 6270 Setup Setup allows you to adjust the touch screen contrast and/or adjust the 6270 speaker volume.
SECTION 4: Initial Setup SCREEN ACTION 3. Press the SETUP button on the "More Choices" screen. The "Setup" screen is displayed. 4. Adjust the touch screen options as described in the paragraphs that follow. How to Adjust the Touch Screen Contrast You may adjust the touch screen contrast as follows: If… Then… you want to increase contrast press the slide bar above the current contrast setting. you want to decrease contrast press the slide bar below the current contrast setting.
6270 Installation and Setup Guide CONTRAST SLIDE BAR INDICATOR 6270-006-V0 Touch Screen Contrast Control How to Adjust the Volume You may adjust the 6270 speaker volume by pressing your finger on the touch screen slide bar associated with the "Volume" scale and doing the following: If… Then… you want to increase volume press the slide bar above the current volume setting. you want to decrease volume press the slide bar below the current volume setting.
SECTION 4: Initial Setup How to Select Screen Saver Activation Time When the 6270 is not armed and not active, it will automatically go into screen saver mode (display goes blank) after the selected blank display time has expired (unless you select “never”). To select the time after which the screen will go blank, do the following: SCREEN ACTION 1. Press the Blank Display After: "arrow" button. A pull-down menu displaying the time period options is displayed. 2.
6270 Installation and Setup Guide SCREEN ACTION When the Update is complete the 6270 goes to the "Home" screen or "More Choices" screen depending on whether you pressed the "Home" or "Back" button, respectively ("More Choices" screen shown). How to Set the Time and Date You can set the time and date from the Set Time & Date screen. Pressing the Time and Date bar located at the bottom of each 6270 screen displays the Set Time & Date screen. When the time is set it will be stored in the 6270 only.
SECTION 4: Initial Setup INCREASE BUTTON (TYPICAL) DECREASE BUTTON (TYPICAL) CANCEL BUTTON OK BUTTON 6270-008-V0 Set Time & Date Screen When all settings have been completed, select Ok to save the settings or Cancel to discard the settings that have been entered. Setting Chime Mode On/Off Operating modes allows you to turn the 6270 chime mode on or off.
6270 Installation and Setup Guide SCREEN ACTION 3. Press the OPERATING MODES button on the "More Choices" screen. The "User Authorization" screen is displayed with the instructions "Enter Authorized Code". 4. Enter your “Installer” code. The "Operating Modes" screen is displayed. 5. Touch the Chime Mode button to turn the Chime Mode on or off. A checkmark appears in the button when the Chime Mode is “ON”. Press the “HOME” or “BACK” button after making your selection.
S E C T I O N 5 User Codes x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In This Section ♦ Introduction to User Code Setup ♦ How to Access User Setup x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Introduction to User Code Setup Each user must be assigned a name with a corresponding 4-digit user code in order to gain access to various features and functions.
6270 Installation and Setup Guide SCREEN ACTION 2. Press the MORE CHOICES button. The "More Choices" screen is displayed. 3. Press the SETUP button on the "More Choices" screen. The "Setup" screen is displayed. 4. Press the USER SETUP button on the “Setup” screen. The User Setup screen is displayed. 5–2 WWW.DIYALARMFORUM.
SECTION 5: User Codes How to Add a User Add a User as follows: SCREEN ACTION 1. To add a user, press the ADD USER button. The "User Authorization" screen is displayed with the instructions "Enter Authorized Code". 2. Enter your Authorized code. The “User Options” screen is displayed. Note: The authorized code for adding users is dependent upon the alarm panel you are interfacing with. Check your alarm panel Installation and Setup Guide to determine who can add users. 3.
6270 Installation and Setup Guide SCREEN ACTION 4. Type in the user name (6 characters max.) and press the OK button. The “User Options” screen is displayed with Enter User Code… displayed. 5. Touch the box next to Enter User Code… The "User Authorization" screen is displayed with the instructions "Enter 4 Digits". 6. Enter the 4-digit code for this user. The “User Options” screen is displayed with the user’s name and code displayed. 7.
SECTION 5: User Codes SCREEN ACTION 8. Press the Save button. The system will save the configuration. When the save is complete, the User Setup screen is displayed with the new user’s name shown. How to Delete a User Delete a User as follows: SCREEN ACTION Three selections are available: add a user, edit a user, or delete a user. 1. To delete a user, touch the circle next to the user to be deleted and press the DELETE USER button.
6270 Installation and Setup Guide SCREEN ACTION 3. Press the appropriate button. The User Setup screen is displayed. How to Edit a User Edit a User as follows: SCREEN ACTION Three selections are available: add a user, edit a user, or delete a user. 1. To edit a user, touch the circle next to the user to be edited and press the EDIT USER button. The "User Authorization" screen is displayed with the instructions "Enter Authorized Code". 5–6 WWW.DIYALARMFORUM.
SECTION 5: User Codes SCREEN ACTION 2. Enter your Authorized code. The “User Options” screen is displayed. Note: The authorized code for deleting, adding, and editing users is dependent upon the alarm panel you are interfacing with. Check your alarm panel Installation and Setup Guide to determine who can delete, add, and edit users. 3. Select whatever options you wish to select for this user and press the Save button. The configuration changes are saved and you are returned to the User Setup screen.
6270 Installation and Setup Guide 5–8 WWW.DIYALARMFORUM.
S E C T I O N 6 Maintenance x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In This Section ♦ About 6270 Maintenance ♦ Routine Care ♦ How to Clean the 6270 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x About 6270 Maintenance With the exception of normal cleaning, the 6270 is maintenance free. How to Clean the 6270 IMPORTANT: Do not use an abrasive cleaning agent or abrasive cloth when cleaning the 6270 or damage to the touch screen may occur.
6270 Installation and Setup Guide SCREEN ACTION 3. Press the SETUP button on the "More Choices" screen. The "Setup" screen is displayed. 4. Press the CLEAN SCREEN button. A pop-up window displaying “Touch Screen will be disabled so that you may wipe the screen clean. Please use a damp, soft cloth. DO NOT use any liquids, sprays, or ammonia-based cleansers. Press CONTINUE to disable touchscreen. When the Continue button is pressed the “Touch Screen Disabled for => 30 Seconds”.
SECTION 6: Maintenance Routine Care x x x Treat the components of the security system as you would any other electrical equipment. Do not slam sensor-protected doors or windows. Keep dust from accumulating on the keypad and all protective sensors, particularly on motion sensors and smoke detectors. The keypad and sensors should be cleaned carefully with a dry soft cloth. Do not spray water or any other fluid on the units. 6–3 WWW.DIYALARMFORUM.
6270 Installation and Setup Guide 6–4 WWW.DIYALARMFORUM.
S E C T I O N 7 Troubleshooting x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In This Section ♦ Troubleshooting ♦ Performing Diagnostics ♦ Diagnostics x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Troubleshooting For troubleshooting procedures, refer to the Control Panel Installation Guide. Diagnostics About Diagnostics A series of diagnostic tests are provided that allows verification of correct operation of the 6270 and its connections to the security system.
6270 Installation and Setup Guide SCREEN ACTION 3. Press the SETUP button on the "More Choices" screen. The "Setup" screen is displayed. 4. Press the Advanced Setup button on the "Setup" screen. The Enter Authorized Code: authorization screen is displayed. 5. Enter your 4-digit Installer code. The "Advanced Setup" menu screen is displayed. 6. Press the Diagnostics button on the "Advanced Setup" menu screen. The "Diagnostics" screen is displayed. 7–2 WWW.DIYALARMFORUM.
SECTION 7: Troubleshooting SCREEN ACTION Performing Diagnostics Select any diagnostic test from the Diagnostics screen by pressing its associated Test button. All or any individual test may be run when you access the Diagnostics screen; however, each test must be performed one at a time. At any time when a test is not being performed, you can press: x x the back button to return to the previous screen, or the home button to return to your home page.
6270 Installation and Setup Guide SCREEN ACTION 2. When you press the Yes or No button accordingly, automatically a pop-up "Confirmation Window" is displayed in the center of the screen with an all white background. Within the Confirmation Window the question "Is Screen Background White?" is displayed. 3. When you press the Yes or No button accordingly, automatically a pop-up "Confirmation Window" is displayed in the center of the screen with the background in 16 shades of gray.
SECTION 7: Troubleshooting SCREEN ACTION 5. When you press the Yes or No button accordingly, the "Diagnostics" screen is displayed with the LCD Display Test results ("Passed" or "Failed") shown in the test status column. Note: If the response was no (the No button is pressed) to any question of this test, when the system is returned to the Diagnostics screen, "Failed" is displayed in test status column. 7–5 WWW.DIYALARMFORUM.
6270 Installation and Setup Guide Audio Test Perform the Audio Test as follows: SCREEN ACTION When you press the Test button associated with the Audio Test "Testing.." is displayed in the test status column on the "Diagnostics" screen while beeps sound from the speaker. At the conclusion of the test, a pop-up "Confirmation Window" is displayed in the center of the "Diagnostics" screen. Within the Confirmation Window the question "Did you hear Beep?" is displayed.
SECTION 7: Troubleshooting LED Test Perform the LED Test as follows: SCREEN ACTION 1. When you press the Test button associated with the LED Test, "Testing.." is displayed in the test status column on the "Diagnostics" screen while the 3 LEDs light sequentially, top to bottom (red, green, amber), 5 times. At the conclusion of the test, a pop-up "Confirmation Window" is displayed in the center of the "Diagnostics" screen. 2.
6270 Installation and Setup Guide SCREEN ACTION 7–8 WWW.DIYALARMFORUM.
S E C T I O N 8 Specifications x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Specifications MECHANICAL Dimensions: Width: 6 ¼ inches Height: 5 inches Depth: 1 • inches ELECTRICAL Operating Voltage: Current Drain: Backlight OFF, Sound OFF Backlight ON, Sound OFF Backlight ON, Sound ON 180mA 190mA 210mA 8–1 WWW.DIYALARMFORUM.
6270 Installation and Setup Guide 8–2 WWW.DIYALARMFORUM.
S E C T I O N 9 Index x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x About the 6270 ................................................................................................. 1–1 Address Change....................................................................................... 4–2, 4–5 Central Station Screen Accessing ..................................................................................................... 4–3 Chime Mode .............................................
6270 Installation and Setup Guide Electrical ....................................................................................................... 8–1 Mechanical.................................................................................................... 8–1 System Features............................................................................................... 1–1 System Options Selecting.......................................................................................................
NOTES WWW.DIYALARMFORUM.
NOTES WWW.DIYALARMFORUM.
NOTES WWW.DIYALARMFORUM.
NOTES WWW.DIYALARMFORUM.
NOTES WWW.DIYALARMFORUM.
NOTES WWW.DIYALARMFORUM.
NOTES WWW.DIYALARMFORUM.
NOTES WWW.DIYALARMFORUM.
NOT USED NOT USED DATA OUT +12VDC GND DATA IN USER INTERFACE + + + + + + BLACK CONTROL TERMINAL STRIP SUPPLEMENTARY POWER SUPPLY + _ AUX + _ AUX DATA DATA IN OUT BLACK RED GREEN YELLOW 6270-004-V0 UL Use a Listed Class 2 power supply suited for the application. Summary of Connections WWW.DIYALARMFORUM.
LIMITED WARRANTY Honeywell International Inc.