Setup guide
K14117 3/06 Rev. A 
  ADEMCO LYNXR-I
 Security Systems 
Quick Start Guide 
U
UU
U
L
LL
L
LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N 
LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed. 
Introduction 
This Quick Start Guide can help you install the rechargeable LYNXR-I quickly and easily by providing the basic 
steps for installation using the built-in defaults. For more detailed information and important notes, refer to the 
LYNXR-I Installation and Setup Guide. 
The following steps assume that one of the system’s default tables will be used. 
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the 
Installation Instructions. 
Default Table Summary 
Zone  Table 1  Table 2  Table 3  Table 4 
2  front door  front door  front door  front door 
3  back door  back door  back door  back door 
4  window  garage door  window  window 
5  motion detector  motion detector  window  window 
6  -------  smoke detector  window  window 
7  -------  -------  window  window 
8  -------  -------  motion detector  motion detector 
9  -------  -------  smoke detector  smoke detector 
26  loop 3 arm away  loop 3 arm away  loop 3 arm away  loop 3 arm away 
27  loop 2 disarm  loop 2 disarm  loop 2 disarm  loop 2 disarm 
28  loop 4 arm stay  loop 4 arm stay  loop 4 close device  loop 4 close device 
29  loop 1 no alarm response  loop 1 no alarm response  loop 1 no alarm response  loop 1 no alarm response 
30  loop 3 arm away  loop 3 arm away  loop 3 arm away  loop 3 arm away 
31  loop 2 disarm  loop 2 disarm  loop 2 disarm  loop 2 disarm 
32  loop 4 arm stay  loop 4 arm stay  loop 4 close device  loop 4 close device 
33  loop 1 no alarm response  loop 1 no alarm response  loop 1 no alarm response  loop 1 no alarm response 
92  duress  duress  duress  duress 
99  silent alarm  audible alarm  silent alarm  silent alarm 
Master User Code  1-2-3-4  1-2-3-4  1-2-3-4  1-2-3-4 
Installer Code  4-1-1-2  4-1-1-2  4-1-1-2  4-1-1-2 
Duress Code  ------  ------  ------  ------ 
Entering Expert Program Mode: installer code + 8 0 0 
Interactive Mode  Used to Program 
*
56 Enhanced Zone Programming  Zone characteristics, report codes, and serial numbers
*
83 Enhanced Sequential Mode  5800 Series transmitter serial numbers 
*84 Assign Zone Voice Descriptors  Voice descriptors for each zone 
Exiting Program Mode:
 *
98 inhibits re-entry into the Programming mode using the Installer Code. 
 *
99 allows re-entry into the Program mode using Installer Code + 8 0 0. 
NOTES:  •  Table 4 supports the automatic paging feature (open/close events reported to pager phone number),and a Powerline Carrier Device programmed 
as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a 
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions. 
•  Primary and secondary report format for all tables is Ademco’s Contact ID® reporting. 
•  Tables 1, 3 and 4 record only alarms, alarm restores, troubles, and trouble restores in the event log. Table 2 records all events in the event log. 