User guide
– 47 – 
Summary Of Audible Notification
Summary Of Audible NotificationSummary Of Audible Notification
Summary Of Audible Notification 
*UPPER CASE indicates announcements after pressing STATUS once. Lower case indicates announcements after 
pressing STATUS twice. 
SOUND CAUSE  DISPLAY  ANNOUNCEMENT* 
INTERRUPTED 
Speaker and 
external piezo and 
bell 
FIRE ALARM FIRE ALARM is displayed; zone 
number in alarm displayed. 
fire alarm + zone voice 
descriptor 
(Voice descriptor is 
interlaced with the siren and 
sounds every 45 seconds) 
CONTINUOUS 
Speaker and 
external piezo and 
bell 
BURGLARY/AUDIBLE 
EMERGENCY ALARM 
ALARM  is displayed; zone number 
in alarm displayed. 
alarm + zone voice 
descriptor 
(Voice descriptor is 
interlaced with the siren and 
sounds every 45 seconds) 
ONE SHORT BEEP 
(not repeated) 
Speaker and 
external piezo 
a. SYSTEM DISARM 
b. SYSTEM ARMING 
ATTEMPT WITH AN 
OPEN ZONE. 
c. BYPASS VERIFY 
a. Green LED on steady 
b. The number of the open protection 
zone is displayed after pressing 
STATUS. 
c. Numbers of the bypassed 
protection zones are displayed 
(One beep is heard for each zone 
displayed). 
a. DISARMED–READY TO 
ARM 
b. DISARMED–NOT READY 
TO ARM 
c. zones bypassed 
ONE SHORT BEEP 
(once every 45 
secs) Speaker and 
external piezo 
a. SYSTEM IS IN TEST 
MODE 
b. LOW BATTERY AT A 
TRANSMITTER 
c. SYSTEM LOW 
BATTERY 
d. FAIL TO 
COMMUNICATE 
a. Opened zone identifications will 
appear. 
b. LOW BAT displayed with zone 
number of transmitter. 
c. LOW BAT displayed with no zone 
no. 
d. FC displayed with no zone no. 
a. No announcement 
b. low battery + zone voice 
descriptor 
c. system low battery 
d. check system 
TWO SHORT 
BEEPS 
Speaker and ext. 
piezo 
A
RM AWAY OR MAXIMUM  AWAY or AWAY + INSTANT is 
displayed. Red ARMED indicator is 
lit. 
ARMED AWAY [INSTANT] – 
EXIT NOW 
THREE SHORT 
BEEPS 
Speaker and 
external piezo 
a. ARM STAY OR INSTANT 
b. ZONE OPENED WHILE 
SYSTEM IS IN CHIME 
MODE. 
a. STAY or STAY + INSTANT is 
displayed. Red ARMED indicator is 
lit. 
b. CHIME displayed, number of open 
protection zone will be displayed if 
the Status key is pressed. 
a. ARMED STAY [INSTANT] 
– EXIT NOW 
b. zone voice descriptor 
RAPID BEEPING 
Speaker and 
external piezo 
a. TROUBLE 
b. MEMORY OF ALARM 
a. FAULT displayed. Number of 
troubled protection zone is 
displayed. 
b. FIRE ALARM or ALARM is 
displayed; zone number in alarm is 
displayed. 
a. fault + zone voice 
descriptor 
b. fire alarm or alarm + zone 
voice descriptor 
SLOW BEEPING 
Speaker and 
external piezo 
a. ENTRY DELAY 
WARNING 
b. EXIT DELAY WARNING 
a. Exceeding the delay time without 
disarming causes alarm. 
b. AWAY or AWAY + INSTANT is 
displayed 
a. DISARM SYSTEM NOW 
b. ARMED [AWAY] 
[INSTANT] – EXIT NOW 