/<1;5 /<1;5 6HFXULW\ 6\VWHPV 8VHU *XLGH OFF AWAY STAY AUX ® ® K5481V1 9/01
7$%/( 2) &217(176 SYSTEM OVERVIEW ...............................................................................................................................3 Features ..................................................................................................................................................3 General Operation ..................................................................................................................................4 Quick View of System Functions ..........
6<67(0 29(59,(: Features General Information This system offers you three forms of protection: burglary, fire, and emergency, depending on the configuration of your system. The system consists of a master keypad for controlling system operation, various wireless sensors which provide perimeter and interior burglary protection, and optional smoke or combustion detectors to provide early fire warning.
6<67(0 29(59,(: General Operation Zones Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your entry/exit door may have been assigned to zone 01, sensing devices on windows in the master bedroom to zone 02, and so on. These numbers appear on the display when an alarm or trouble condition occurs. 8/ LYNXR is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed.
48,&. 9,(: 2) 6<67(0 )81&7,216 NOTE: = Boxes represent the entering of your 4-digit user code.
48,&. 9,(: 2) 6<67(0 )81&7,216 To remotely activate forced bypass: ------- + [6] + [#]* To remotely check system status: ---------- [*] To hang up: ------------------------------------- + [9] *If forced bypass was enabled by your installer.
6<67(0 29(59,(: About the Master Keypad General IMPORTANT: If the keypad beeps rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. The keypad allows you to control all system functions. The keypad features telephone-style keys and a Liquid Crystal Display (LCD), which shows the nature and location of all occurrences.
6<67(0 29(59,(: About the Display and Indicators Display Definitions (for other displays, see Trouble Messages) ALARM: AWAY: INSTANT: STAY: 8/ LYNXR is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed. FIRE: LOW BAT: AC: CHIME: TEST: REC: MESSAGE: BYPASS: FAULT: PC: Appears when an intrusion has been detected and the system is armed (also appears during a fire alarm or AWAY LOW BAT AC INSTANT CHIME TEST audible emergency alarm).
6<67(0 29(59,(: Master Keypad Definitions 20 21 3 2 1 4 19 5 OFF 18 AWAY STAY 17 AUX ARMED READY 1 2 3 RECORD VOLUME PLAY 4 5 6 LIGHTS ON TEST BYPASS 7 8 9 LIGHTS OFF CODE CHIME * 0 # NO DELAY FUNCTION STATUS 6 7 8 ® 9 16 15 14 13 12 11 10 01000-022-V0 IMPORTANT!: When you use the keypad to enter codes and commands, press the keys within 2 seconds of one another.
6<67(0 29(59,(: Master Keypad Definitions NOTE: The system functions described below are for reference only, and require additional key entries to activate. 1. 2. 3. 4. DISPLAY WINDOW: Liquid Crystal Display (LCD). Displays protection point identification and system status, messages, and user instructions. ARMED INDICATOR: (RED) Lit when the system has been armed (STAY, AWAY, NO DELAY). Blinks when armed and fault exists.
6(&85,1* 7+( 35(0,6(6 Checking System Status General Information Before arming your system, all protected doors, windows, and other protection zones must be closed or bypassed (see the BYPASSING PROTECTION section). Pressing the STATUS key will announce all zones that are faulted, as well as any other abnormal system condition, making it easier for you to secure any open zones. READY LIGHT: The green READY indicator on the keypad will be lit if the system is ready to be armed.
6(&85,1* 7+( 35(0,6(6 Arming the System Arming in Stay Mode Use this mode when you are staying home, but expect someone to use the entrance door later. Close all protected perimeter windows and doors before arming. The green READY indicator on the keypad should be lit if the system is ready to be armed. To arm in STAY mode: + STAY or press and hold STAY ** Your user code** ** See Quick Arming paragraph. The keypad beeps three times and displays the armed STAY message.
6(&85,1* 7+( 35(0,6(6 Arming the System Arming the System With No Delay Use NO DELAY with STAY mode when you are staying home and do not expect anyone to use the entrance door. Use NO DELAY with AWAY mode when the premises will be vacant for extended periods of time such as vacations, etc. When armed with NO DELAY, the system will sound an alarm if a protected door or window is opened, including the entrance door.
6(&85,1* 7+( 35(0,6(6 Entry/Exit Delays Exit Delay Exit delay begins immediately after arming the system, and gives you time to leave through the designated exit door without setting off an alarm. A slow beeping will sound throughout the exit delay period, if programmed. Exit Alarms Exit Alarm Active To minimize false alarms sent to the alarm monitoring company, your system may have been programmed for this feature. Ask your installer if Exit Alarm is active for your system.
6(&85,1* 7+( 35(0,6(6 Disarming the System Use the OFF key to disarm the system and to silence alarm and trouble sounds. See the SUMMARY OF AUDIBLE NOTIFICATION section for information, which will help you to distinguish between fire and burglary alarm sounds. IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location.
6(&85,1* 7+( 35(0,6(6 Bypassing Protection Zones Bypassing Individual Zones Use the BYPASS key when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful.
6(&85,1* 7+( 35(0,6(6 Panic Keys / Chime Mode Panic Keys Your system may have been programmed to use special keys to manually activate panic functions. The functions that might be programmed are listed below. See your installer for the function(s) that may have been programmed for your system. Active Panic Functions Keys Zone Function Your installer should note the functions that 1 and ✴ 95 are active in your 3 and # 96 system.
86(5 )81&7,216 Paging Feature Automatic Paging If the Paging feature has been programmed for your system, your pager will respond to certain conditions as they occur in your system by displaying a message that indicates the type of condition that has occurred. The message appears in a 7-digit format explained below. The system can also be programmed to send up to 16 additional digits that will appear in front of the 7-digit message.
86(5 )81&7,216 Using Powerline Carrier Device Commands (Lights On/Lights Off Keys) General Information Your system may be set up so that certain lights or other devices can be turned on or off by using the device command from the keypad. Ask your installer if this has been done in your system. If programmed for your system, some devices may activate automatically upon certain system conditions. In this case, the following commands can be used to override the device activation.
86(5 )81&7,216 Message Recording/Playback/Volume Control Recording a Message Your system can record a brief message (up to 20 seconds) that can be played back later. To record a message: FUNCTION + RECORD The keypad beeps and displays “ REC MESSAGE.” Begin speaking into the microphone. NOTE: The Record function can only be performed from the master keypad. It cannot be performed from any other wireless keypad (ex. 5827).
86(5 )81&7,216 AUX FUNCTION General Information The AUX key may have been programmed to either perform a predefined function or to send a preset message to a pager (see PAGER FEATURE section for pager operation). Ask your installer which function has been assigned for your system. AUX Key: PRE-DEFINED FUNCTION PAGING FUNCTION If programmed for the AUX function, you can use the AUX key to activate a string of up to 20 keystrokes that have been stored in the system’s memory.
86(5 )81&7,216 Clock/Calendar Your system can display the current time (see your installer). The date is not displayed, but has an internal function. The system must be disarmed with no faults present. To set the time and date: NOTES: 1. 2. 3. 4. 5. + FUNCTION + [63] Master User Code or Installer Code The keypad beeps twice for invalid data entries (e.g., an hour greater than 12), and the entry will not be accepted. The keypad beeps once for valid entries.
86(5 )81&7,216 Scheduling User Interface Upon getting into the scheduling user interface by entering master or installer code + FUNCTION + “ 64” , the following entries will be sequentially prompted to the user. Note that all inputs are checked for validity upon entry and all invalid entries are rejected. Hitting a “ *” will allow the entries to be accepted and advance to the next field. Hitting a “ #” will reject the entry and back up one field.
86(5 )81&7,216 Scheduling User Interface NOTE: The keypad beeps twice for invalid data entries (e.g.: an hour greater than 12), and the entry will not be accepted. The keypad beeps once for valid entries and four times when a schedule event is programmed successfully. [x] = the value that was last stored in the memory.
86(5 )81&7,216 Scheduling User Interface b : xx xx : bd Begin Time (minute) [xx] = begin minute 0 to 59 [*] = continue [#] = return to previous prompt Begin Day [xx] = begin day 01 to 17 [*] = continue [#] = return to previous prompt • If the value programmed in the Event Identifier is “ 3” , “ 4” , or “ 5” , and the current entry is completed, the system will save all field data up to this field.
86(5 )81&7,216 Scheduling User Interface Event Identifier Entries Entry 0 Event Empty 1 X-10 Device 2 Latch Key Report 3 Automatic Stay Arming 4 Reminder Announcements 5 Alarm Clock Comment No event scheduled (or schedule is temporarily disabled) Turn an X-10 device, either on or off at begin/end times. (will have a start and end time to program) (time driven) NOTE: SH10A siren cannot be used. Send a special pager report (7110000) indicating system not yet disarmed.
86(5 )81&7,216 Scheduling User Interface Day of Week Entries Entry 00 Day Invalid day entry 01 Do event on next time match on the next Monday (will remove itself after executing) 02 Do event on next time match on the next Tuesday (will remove itself after executing) 03 Do event on next time match on the next Wednesday (will remove itself after executing) 04 Do event on next time match on the next Thursday (will remove itself after executing) 05 Do event on next time match on the next Friday (wil
86(5 )81&7,216 Remote Phone Control Feature The LYNXR/LYNXR24 is equipped with a remote interactive phone capability that permits access to the security system from any off-site touch-tone telephone using all user codes. If this feature has been programmed, the system will provide the appropriate voice messages and any system beeping sounds indicating the status of the security system over the phone line. (Refer to Summary of Audible Notification for further information.
86(5 )81&7,216 Remote Phone Control Feature Enter: (within eight seconds) Your user code The system status will be announced. Remote Phone Control Commands + [1] To remotely disarm system: Your user code To remotely arm in AWAY mode: + [2] Your user code To remotely arm in STAY mode: + [3] Your user code To remotely arm in AWAY or STAY mode with no delay: + [2] or [3] + [0] Your user code To remotely activate X-10 devices 1-6: [#] + [4] + device no.
),5( $/$50 6<67(0 (If Installed) 8/ LYNXR is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed. General Your fire alarm system (if installed) is active 24 hours a day, providing continuous protection. In the event of an emergency, the installed smoke and heat detectors will automatically activate your security system, triggering a loud, intermittent sound from the keypad.
),5( $/$50 6<67(0 National Fire Protection Association’s Smoke Detector Recommendations 8/ LYNXR is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed. With regard to the number and placement of smoke and heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #74 noted below.
),5( $/$50 6<67(0 Emergency Evacuation 8/ LYNXR is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed. Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants. 2. Determine two means of escape from each room.
6<67(0 )81&7,216 Security Codes General Information For additional security, users other than you who do not need to know your code can be assigned different security codes. These secondary users are identified by "user numbers" when their codes are assigned. You can assign up to 6 user codes (2-digit user numbers 03-08). Note that the master (primary) user of the system is the only one who can assign codes to secondary users, and is designated user no. 02; user no. 01 is the installer’s code.
6<67(0 )81&7,216 Testing the System (to be conducted weekly) Entering Test Mode The TEST key puts your system into the Test mode, which allows each protection point to be checked for proper operation. The keypad sounds a single beep every 45 seconds as a reminder that the system is in the Test mode. NOTE: An alarm message will not be sent to your alarm monitoring company during the following tests. Disarm the system and close all protected windows, doors, etc.
6<67(0 )81&7,216 Trouble Messages Typical Trouble Condition Displays To silence the beeping sound for fault conditions, press any key. FAULT Indicates that a problem exists with the zone(s) displayed, accompanied by rapid beeping. First, determine if the zone(s) displayed are intact and make them so if they are not. If the zone uses a wireless detector, check that changes in the room (moving furniture, televisions, etc.) are not blocking wireless signals from the detector.
6<67(0 )81&7,216 Maintaining your system The components of your security system are designed to be as maintenance-free as possible. To make sure that your system is in working condition, do the following: 1. Test your system weekly. 2. Test your system after any alarm occurs (see the TESTING THE SYSTEM section). Low Battery Conditions in Wireless Sensors Each wireless sensor in your system has a 9-volt or 3-volt battery.
6XPPDU\ 2I $XGLEOH 1RWLILFDWLRQ ** UPPER CASE indicates announcements after pressing STATUS once, Lower case indicates announcements after pressing STATUS twice. SOUND CAUSE DISPLAY INTERRUPTED Speaker and external piezo and bell CONTINUOUS Speaker and external piezo and bell ONE SHORT BEEP (not repeated) Speaker and external piezo FIRE ALARM FIRE ALARM is displayed; zone number in alarm displayed. ONE SHORT BEEP (once every 45 secs) Speaker and external piezo TWO SHORT BEEPS Speaker and ext.
UL NOTICE: This is a " Grade A" residential system. FCC ID: CFS8DLLYNX RADIO FREQUENCY EMISSIONS Federal Communications Commission (FCC) Part 15 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Industry Canada This Class B digital apparatus complies with Canadian ICES-003.
OWNER'S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit. A. GENERAL INFORMATION: Insured's Name and Address: Insurance Company: Policy No.: ADEMCO's LYNXR/LYNXR24______________________________Other Type of Alarm: Burglary Installed by: Fire Both Serviced by: Name Name Address Address B. NOTIFIES (Insert B = Burglary, F = Fire) Local Sounding Device Central Station Police Dept. Fire Dept.
OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.) E. SMOKE DETECTOR LOCATIONS Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall All Exterior Doors F. BURGLARY DETECTING DEVICE LOCATIONS: Front Door Basement Door Rear Door 1st Floor Windows All Windows Interior Locations All Accessible Openings, Including Skylights, Air Conditioners and Vents G.
,1'(; A AC.....................................................................8 Adjusting the Volume.....................................20 Alarm............................................................4, 8 Alarm Monitoring Company...........................17 ARMED Indicator ..........................................10 Audible Emergency ........................................17 AUX Function ............................................6, 21 AUX Key.......................................................
P Pager...........................................................6, 21 Pager Code......................................................18 Pager Feature........................................3, 18, 21 Panic Key..........................................................3 Personal Emergency .......................................17 Phone Control.............................................3, 28 Play Back a Message ........................................5 Silence Alarm .......................................
SERVICING INFORMATION Your local ADEMCO dealer is the person best qualified to service your alarm system. Arranging some kind of regular service program with him is advisable.
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: • Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device. • Intrusion detectors (e.g.
ADEMCO ONE YEAR LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its security equipment (the "product") to be free from defects in materials and workmanship for one year from date of original purchase, under normal use and service.
-NOTES- – 46 –
-NOTES- – 47 –
165 Eileen Way, Syosset, New York 11791 Copyright © 2001 PITTWAY CORPORATION ¬.