Installation manual

3
PROGRAMMING FORM
Entry of a number other than one specified will give unpredictable results. Default values are shown in brackets, with unique table 1 and table 2
values indicated where applicable (DT1 = default table 1; DT2 = default table 2); see page 20 for a complete list of factory default tables 1 and 2.
20
Installer Code [4112] | | |
09 = 4 digit installer code
21
Quick Arm Enable DT1: [1,1,1] DT2: [0,0,0]
0 = no quick arm; 1 = allow quick arm Part. 1 Part. 2 Com
22
RF Options [0,0]
Entry 1 - 0 = no RF Jam detection; 1 = detect RF Jam Jam Supv
Entry 2 supervision interval; 0 = 12 hour; 1 = 2 hour; 2 = 20 min if
disarmed/2 hrs if armed; 3 = 12 hrs for burg zones/3 hrs for fire zones
23 Quick (Forced) Bypass [0,0,0]
0 = no quick bypass Part. 1 Part. 2 Com
1 = allow quick bypass (code + [6] + [#])
24 RF House ID Code [00,00,00] | | |
00 = disable all wireless keypad usage Part. 1 Part. 2 Com
0131 = house ID for use with 5827, 5827BD keypad or
5804BD/5804BDV keyfob
25 Arming Prevention Override [7,0]
If no override is selected, system will not arm when there is either a
supervision failure, system low battery, AC loss, or tamper.
Entry 1 0 = no arming prevention override
1 = allow system to arm with an RF supervision failure
2 = allow system to be armed with an AC Mains Loss
4 = allow system to be armed with a system low battery
E.g., To select arm with supervision failure and system low
battery, enter 5 (1 + 4);
Entry 2 0 = no tamper override (see field *175 for more tamper options)
1 = allow system to be armed with a tamper fault
2 = allow system to be armed with a tamper fault once
NOTE: If tamper option 1 or 2 is selected, field *175 digit 2 must be 0.
26 Chime By Zone [0]
0 = no; 1 = yes (select chime zones on zone list 3, see *81 Menu mode)
27
Powerline Carrier (X–10) House Code [0]
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I, 9 = J,
#10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P
29 ECP Contact ID Output for ACM
[0]
0 = no; 1 = use Contact ID output on ECP terms. (e.g. TCP-IP ethernet)
31 Single Alarm Sounding/Zone [1]
0 = no; 1 = yes, only one alarm sounding per armed period per zone
32 Fire Alarm Sounder (Bell) Timeout
[0]
0 = sounder stops at timeout; 1 = no sounder timeout
33 Siren (Burglary) Timeout
[3]
0=none; 1 =1 min; 2 =2 min; 3 =3 min; 4 =4 min; 5 =8 min; 6 =16 min
34 Exit Delay
[60,60,60]
00 to 96 = 00 to 96 seconds respectively Part 1 Part 2 Com
97 = 120 seconds
35 Entry Delay 1 (zone type 01) [15,15,15]
00 to 96 = 00 to 96 seconds respectively Part 1 Part 2 Com
97 will = 120 seconds; 98 will = 180 seconds; 99 will = 240 seconds
36 Entry Delay 2 (zone type 02) [30,30,30]
See *35 for entries. Part 1 Part 2 Com
37 Audible Exit Warning
0 = no; 1 = yes DT1: [0,0,0] DT2: [1,1,1] Part 1 Part 2 Com
38 Confirm. Arming Ding [03, 03, 03] | | |
Entry 1 for each partition selects Part 1 Part 2 Com
whether arming from wired keypads causes siren ding:
0 = no; 1 = yes, ding and siren for time selected in entry 2
Entry 2 for each partition selects whether arming from keyswitch and/or
remote RF devices causes siren ding and/or activates trigger 2 output;
also selects ding/trigger activation duration (arm = 2 dings of selected
duration with 1 second off between; disarm = 1 ding of selected
duration).
(field *38 continued at top of next column)
38 Confirm. Arming Ding (continued)
(continued) Enter 0-15 from table.
Entry Ding at Siren Trigger 2 Output
0 none none NOTE:
1 none 250mS If using trigger 2
2 none 1 second output for arming
3 none 4 seconds ding, do not assign
4 250mS none any other functions
5 250mS 250mS to trigger 2.
6 250mS 1 second
7 250mS 4 seconds
8 1 second none
9 1 second 250mS
#+10 1 second 1 second
#+11 1 second 4 seconds
#+12 4 seconds none
#+13 4 seconds 250mS
#+14 4 seconds 1 second
#+15 4 seconds 4 seconds
39 Power-Up In Previous State [1]
0 = always power-up disarmed; 1 = power-up in previous state
For dialer fields 40 42, enter the number of digits shown. Do not fill
unused spaces. Enter 09; #+11 for ''; #+12 for '#'; #+13 for a 2-second
pause. If fewer than the maximum digits entered, exit the field by pressing [ ].
The next data field is displayed.
40 PABX Access Code | | | | |
Enter up to 6 digits. If fewer than 6 digits are entered, exit by pressing
[]. To clear entries from field, press 40
41 Primary Phone No.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
42 Second Phone No.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Enter up to 30 digits for each phone number. To clear entries, press
41 or 42 respectively.
For fields *43, *44 , *45, *46, *51 and *52, enter 4, 6 (Robofon 8), or 10
digits, depending on selection in *48 Report Format. Enter 09; #+11 for B;
#+12 for C; #+13 for D; #+14 for E; #+15 for F. To clear entries from field,
press *43*, *44*, *45*, *46*, *51* or*52* respectively. Examples: For Acct.
1234, enter 1 | 2 | 3 | 4 ; For Acct. B234, enter #+11| 2 | 3 | 4
43 Primary Subscriber ID # (Part. 1)
| | | | | | | | |
44 Secondary Subscriber ID # (Part. 1)
| | | | | | | | |
45 Primary Subscriber ID # (Part. 2)
| | | | | | | | |
46 Secondary Subscriber ID # (Part. 2)
| | | | | | | | |
47 Phone System Select/Dialer Attempts
Phone System Select: [1,6] Select Attempts
If Cent. Sta. IS NOT on a satellite link: 0=Pulse Dial; 1=Tone Dial;
if Cent. Sta. IS on a satellite link: 2 = Pulse Dial ; 3 = Tone Dial
Dialer Attempts: 1 10 (for 10, enter #+10)
48 Report Format [7,7]
0 = 3+1,4+1, ADEMCO L/S STANDARD
prim. second
1 = 3+1,4+1, RADIONICS STANDARD NOTES: To enable
2 = 4+2, ADEMCO L/S STANDARD audio beeps format
3 = 4+2, RADIONICS STANDARD (Follow-Me feature),
5 = CID using 10-digit subs account (ID) no. refer to the
System
6 = 4+2, ADEMCO EXPRESS
Communication and
7 = CID using 4-digit subs account (ID) no.
Operation
section in
8 = 3+1,4+1, ADEMCO L/S EXPANDED the Inst.Instr. Also see
9 = 3+1,4+1, RADIONICS EXPANDED *53 and *188 for
#+10 = ROBOFON 8 (6-digit subs account no.) notes on certain
#+11 = ROBOFON Contact ID Contact ID codes.