Example 2.
Pager displays: 1234001005
This indicates that Subscriber No. 1234s system is reporting an opening (001) by User 5 (005).
Note that no Restore Reports are sent to the pager.
Important
: AAV should not be used when Paging or Alarm Reports are being sent to a secondary number.
If this is done, the call to the secondary number by the communicator after the Alarm Report will prevent
the AAV from taking control of the telephone line, and the AAV Listen in session cannot then take place.
FIELD TITLE and DATA ENTRIES EXPLANATION
48
15-Second Dialer Delay (Burglary)
0 = no dialer delay
1 = 15-second delay
Provides delay of BURGLARY ALARM report to the central
station, which allows time for the subscriber to avoid a false
alarm transmission.
U
L
installations:
no dialer delay permitted.
49
Periodic Test Report
0 = no report 2 = weekly
1 = 24-hours 3 = 30 days
Selects the desired test report interval.
U
L
installations:
24 hours (1) must be selected.
50
Sescoa/Radionics Select
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
Select 0 for all other formats.
Selects reporting format.
51
Confirmation of Arming Ding
0 = disables ding
1 = enables 1/2 second ding
2 = enables 1/2 second ding from RF arming
Entering 1 enables 1/2-second ding when closing report
goes in, or at the end of exit delay.
Entering 2 enables 1/2-second ding when RF arming
(this works with either a button RF unit or a 5827).
52
Zone 3 Response Time To Open
0 = 400 milliseconds nominal
1 = 10 milliseconds nominal
Selects response time of sensor in zone 3 to open.
56
Zone Assignment/Alarm Report Codes
This is an Interactive Menu mode that is used
to program
zone numbers
,
zone types
,
alarm and report codes
, and to
identify the
type of loop input device
.
This mode can also be used for entering 5800 Series
transmitter serial numbers (serial numbers can also be
entered using the Expert Programming Mode in
58).
Alpha descriptors can also be entered for zones in
56
(alternatively, alpha descriptors can be entered in menu
mode
82).
58
Expert Programming Mode
Interactive Menu mode used for enrolling
transmitters, programming zone attributes, and
report codes.
Refer to SECTION 5: Zone Programming for procedure.
Refer to the zone assignment table for
56 and
58 in
the Programming Form inserted in this manual.
Programming System Status and Report Codes (
60-
68,
70-
75)
With a 3+1 or 4+1 Standard Format:
Enter a code in the
first digit
box: 19, 0, B, C, D, E, or F.
Enter # + 10 for 0, # + 11 for B, # + 12 for C, # + 13 for D, # + 14 for E, # + 15 for F.
A 0 (
not
# + 10) in the
first digit
box will disable a report.
A 0 (
not
# + 10) in the
second digit
box (if any) will result in automatic advance to the next field when programming.
With an Expanded or 4+2 Format:
Enter codes in
both
boxes (1st and 2nd digits) for 19, 0, or BF, as described
above.
A 0 (
not
# + 10) in the
second
box will eliminate the expanded message for that report
A 0 (
not
# + 10)
in
both
boxes will disable the report.