User`s guide

– 35 –
SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
Alpha Display Keypads
SOUND CAUSE DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
Sounder
Fire Alarm
FIRE
is displayed; descriptor of zone in alarm is
displayed.
LOUD,
CONTINUOUS*
Keypad & Ext.
Sounder
Burglary / Audible Emergency Alarm
ALARM
is displayed; descriptor of zone in alarm
is also displayed.
Also see page 22.
ONE SHORT BEEP
(not repeated)
Keypad only
a. System Disarm
b. System Arm Attempt with an Open Zone
c. Bypass Verify
a.
DISARMED/READY TO ARM
is displayed.
Green READY indicator (if present) is lit.
b. The number and descriptor of the open
protection zone are displayed. Green READY
indicator (if present) is not lit.
c. Numbers and descriptors of the bypassed
protection zones are displayed. (One beep is
heard for each zone displayed.)
Subsequently, the following is displayed:
DISARMED BYPASS Ready to Arm
ONE BEEP
every 40 sec.
Keypad only
a. Low Battery at a Transmitter
b.
System Main Battery Weak
c.
Trouble
a. LO BAT
displayed with description of
transmitter.
b.
LO BAT displayed with no transmitter
description.
c.
CHECK displayed. Descriptor of troubled
protection zone is displayed.
TWO SHORT
BEEPS
Keypad only
Arm Away or Maximum
ARMED AWAY
or
ARMED MAXIMUM
is
displayed. Red ARMED indicator is lit.
THREE SHORT
BEEPS
Keypad only
a.
Arm Stay or Instant
b.
Zone Opened While System in Chime
Mode
c.
Zone Opened While System in Test
Mode
a.
ARMED STAY
or
ARMED INSTANT
is
displayed. Red ARMED indicator is lit.
b.
CHIME
displayed. Pressing [
] and READY
key will display descriptor of opened zone.
c. Open protection zone descriptor is displayed.
RAPID BEEPING
Keypad only
Memory of Alarm
FIRE
or
ALARM
is displayed; descriptor of zone
in alarm is displayed.
SLOW BEEPING
Keypad only
a. Entry Delay Warning
b. Exit Delay Alert
(if programmed)
a.
DISARM SYSTEM OR ALARM WILL
OCCUR
is displayed. Exceeding the delay
time without disarming causes alarm.
b.
ARMED AWAY
or
ARMED MAXIMUM
is
displayed. Slow beeps change to fast beeps
during last 5 seconds of exit delay.
* If bell is used as external sounder, fire alarm is pulsed ring (see page 32); burglary/audible emergency is a steady ring.
Note:
Also see “Other Trouble Displays” and “Total Power Failure” under
TROUBLE CONDITIONS
on pages 30 and 31.