VISTA – 10SEa TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control (C) 2000 Version # .
VISTA – 10a Training Guide Index 1. Basic Feature List 2. Wiring Diagram ……………………..… p. 3 ……………………………. p. 4 3. Programming 3.1 Quick Start Programming Sheet … p. 3.2 Full Programming Form …………….. p. 4. User Functions 5 6 ……………………………. p.10 5. Panel Expansion 5.1 Hard Wired Expansion ………………. 5.2 6128RF Wireless Expansion ……... 5.3 5882 Wireless Expansion ………….. 5.4 Voice Interactive Phone Module .. 5.5 Relay Operation ……………………….. 6. Servicing Vista 10A Training Guide p.11 p.12 p.18 p.24 p.
VISTA 10a Basic Panel Features Ø 6 Hardwired Zones – standard Ø Expands to 22 Zones − Max 14 Zones Hard Wired − Max 16 Zones Wireless (5800 Series) Ø Door Chime Function Ø 7 User Codes Ø 4285 VIP Telephone Module Ø Up to 4 Output Relays Ø Ademco Local Audio Ø Securitel Compatible using Ademco Unistu Vista 10A Training Guide Page 3
2.
3.
Vista 10A Training Guide Page 6
Vista 10A Training Guide Page 7
Vista 10A Training Guide Page 8
Vista 10A Training Guide Page 9
4.
5.1 4219 Hard Wired Expansion Training Module There are three (3) models of Expanders available: They are all fully supervised & have a tampered cover. Ø 4219 will allow another (8) additional Hard Wired zones.
5.
6128RF Local Mode Programming Training Module Key Points: • Use local mode when adding wireless Keypads or wireless keys to an Ademco control that does not support wireless. • Wireless keys enrolled into the 6128RF console are called ‘local keys’ • Local keys are enrolled directly into the 6128RF • The unique serial No. of each key is learnt into the 6128RF − Thus maintaining the added security that unique encoding offers • Local keys do not occupy zones of the control.
6128RF Local Mode Programming Cont…. To Add Local 5804 Keys To 6128RF Enter 6128RF Programming: • Within 30 Secs of powering up the 6128RF, hold down the 1 & 3 keys to enter keypad program mode • “00” and “—“ will be flashing on the display • Press “5” on console to enter Local key programming • “d-“ will be flashing on the display • Select the wireless key device No. to program (1 – 8) • “d1, d2” etc will be displayed depending on the device selected Local Key Programming (Option 5): 1. 2. 4. 5.
6128RF Local Mode Programming Cont…. Loop Number Functions • Press “4” on console to program the loops system function. “A-“ will be displayed. Loop Defaults 1 Relay 2 Sec 2 Disarm system 3 Away Arming 4 Stay Arming • • Enter the loop number (button No.
6128RF Local Mode Programming Cont…. Relay Programming • “d1” will be displayed. Enter “5” on console, if the on board relay is to be programmed. • “o –“ will be displayed • Enter the loop number (button number) that will drive the relay from the pictures on the previous page.
6128RF User Programming Training Module End User Programming • Allows End User to enable or disable wireless keys that have been programmed as local keys • Ideal if a user loses a wireless key Enter User Programming • Ensure Console has been powered up for at least one minute • Press 1 &3 Keys simultaneously for a few seconds • The display will show “d E” & “-“ flashing alternately • Enter device Number (1-8).
5.3 5882 Wireless Expansion Training Module There are three (3) models of 5882: Ø 5882L will permit up eight (8) additional RF zones. Ø 5882M will permit up to sixteen (16) additional RF zones. Ø 5882H will permit up to sixteen (16) additional RF zones. • • • • • • • • Only ONE Wireless Receiver can be used on each System Connect the 5882 (radio receiver) across the console bus.
5882 Wireless Expansion cont…. Training Module RANGE TESTING • • • • Enter GO/NO GO test mode 4111 (Installer Code) # 4 Ensure radio receiver is placed in the correct location (Do not fit receiver until Range Test successfully completed) Check receiver LED for interference After range Testing enter “Code” + “OFF” to exit test mode.
5804 Four Button Remote Training Module • • Connect 5882 wireless receiver across the console bus. Set the 5882dip Switches for address “0” all switches OFF) Enter Panel Programming • • • • • • • • • Select zone number 10 or higher Learn in 5804 butto ns to system Program address *22 and enter “2” for 5800 series wireless Go to address *56 Each Button is a separate zone.
5804 Wireless Bi Directional Remote Training Module • • • Connect 5882 wireless receiver across the console bus. Set the 5882 dip Switches for address “0” all switches OFF). Connect the 5800 TM to the console bus of Partition 1. The 5800 TM must be mounted outside of the Control Panel Cabinet No addressing of the 5800 TM is required. Enter Panel Programming • • • • • • • Program location *22 and enter “2” for 5800 series wireless Program location *24 and program the RF house ID.
5827 Wireless Keypad Training Module • • Connect 5882 wireless receiver across the console bus. Set the 5882 dip Switches for address “0” all switches OFF). Enter Panel Programming • • Program location *22 and enter “2” for 5800 series wireless Program location *24 and program the RF house ID. 2-digit entry is required. (Between 01-32) - It is advisable that House Codes 01, 10 & 31 not be used as these are most frequently used by Installers not doing a House ID sniffer mode test.
5827 Bi Directional Wireless Keypad Training Module • • • • Connect 5882 wireless receiver across the console bus. Set the 5882 dip Switches for address “0” all switches OFF). Connect the 5800 TM to the console. The 5800 TM must be mounted outside the Control Panel cabinet. No addressing of the 5800 TM is required. The three buttons across the top can be used for Fire, Panic, Emergency type Events.
5.4 4285 Voice Interactive Phone Module Training Module • • • • Do not mount the 4285 inside the cabinet door above the control panel PCB. Connect 4285 Voice Interactive Phone module across the console bus. Connect the panel to the “C Com” jack on the 4285 line interface using the cable supplied with the 4285. Take the cable previously used for the “mode 3” connection, and connect directly to “Wall” jack on the 4285.
5.5 4204 Relay Programming Training Module • • • • • • • • • • • • • Connect the Relay module across the console bus. Set 4204’s DIP switch to device address 01 (switch 2 OFF and switches 3, 4, and 5 ON). Switch 1 determines the unit’s cover tamper response (ON= disabled, OFF=enabled). Program Address “* 25” with a 3 for a 4204 (4 Output relay module) Enter * 8 0 to move to “DEVICE PROGRAMMING”. The console will display “ENTER DEVICE No.
6.
Servicing cont…. Training Module IMPORTANT REFER TO SECTION 10. SPECIFICATIONS & ACCESSORIES (Page 36 of 10a Manual) CONSOLE PANICS * & # Zone 07 1 & * Zone 95 3 & # Zone 96 CONSOLE SOUNDER MIMIC Mimics the console beeps for AWAY/STAY arming and OFF commands via an internal piezo sounder.