Security System User's Manual VISTA-50P VISTA-50PUL N5943-6V1 Rev B 4/99
TABLE OF CONTENTS SYSTEM OVERVIEW .................................... 4 General....................................................... 4 A Partitioned System .................................. 4 Zones.......................................................... 4 Fire Protection ............................................ 5 Burglary Protection ..................................... 5 Alarms ........................................................ 6 Memory of Alarm ........................................
TABLE OF CONTENTS (cont’d) ACCESS DOOR CONTROL ........................40 General Information ..................................40 USING #70 RELAY MENU MODE ...............41 General Information ..................................41 USING SCHEDULES ...................................43 Delaying the Closing Time ........................43 Temporary Open/Close Schedules...........43 Programming Temporary Schedules ........44 PROGRAMMING DEVICE TIMERS.............46 General Information .........................
System Overview General Congratulations on your ownership of an Ademco Partitioned Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today. Ademco is the world's largest manufacturer of security systems and millions of premises are protected by Ademco systems. This system offers you three forms of protection: burglary, fire and emergency.
System Overview (cont’d) bedroom to zone 02, and so on. These numbers will appear on the display, along with an alpha descriptor for that zone (if programmed), when an alarm or trouble condition occurs. Fire Protection The fire protection portion of your security system (if used) is always on and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emergency exit routes from your house.
System Overview (cont’d) Alarms When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm. If your system is connected to a central monitoring station, an alarm message will also be sent. To stop the alarm sounding, simply disarm the system. Memory of Alarm When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (ex. FIRE, ALARM).
System Overview (cont’d) in concept to the individual appliance timers that might be purchased at a department store. The devices that can be controlled are programmed into the system by the installer. Up to 16 of these devices can be programmed. Refer to the PROGRAMMING DEVICE TIMERS section for procedures. To Access Another Partition (GOTO Command) Each keypad is assigned a default partition for display purposes, and will show only that partition's information.
System Overview (cont’d) To view the abbreviated instructions: Simply press and hold down the function key of interest until the description starts to appear (about 5 seconds) and then release it. Refer to the FUNCTIONS OF THE KEYPAD section for descriptions of each key function. Phone Access & Voice Response Capability Your system may include a 4285 VIP module that will permit you to access the system via a Touch-tone phone, either on-premises or by call-in when away.
About The Keypads General IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences.
About The Keypads (cont’d) The Fixed-Word Keypad Fixed-Word keypads are functionally identical to alpha keypads, but the LCD display uses pre-designated words to identify the nature and location of occurrences.
Functions Of The Keypad 1. ALPHA DISPLAY WINDOW: A 2line, 32-character Liquid Crystal Display (LCD). Displays protection point identification and system status, messages, and user instructions. 2. AWAY KEY: Completely arms both perimeter and interior burglary protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc.
Functions Of The Keypad (cont’d) 10. CHIME KEY: Turns on & off the CHIME mode. When on, any entry through a protected delay or perimeter zone while the system is disarmed will cause a tone to sound at the Keypad(s). 11. READY KEY: When depressed prior to arming the system, the keypad will display all open protection zones within the keypad's home partition. This key is also used to display all zone descriptors that have been programmed for your system, by holding the key down for at least 5 seconds. 12.
Functions Of The Keypad (cont’d) 5 1 2 3 4 6 15 14 16 ARMED READY A B C OFF AWAY 1 2 STAY 3 MAX TEST BYPASS 4 5 6 INSTANT CODE CHIME 7 8 9 * D LOCATION OF DEDICATED PANIC KEYS. KEY D USED AS SPEED KEY (if programmed) 8 9 10 READY 17 7 0 # PANIC 11 12 13 Note: Unless stated otherwise, most procedures in this manual apply to all keypad types and styles. Some procedures, however, are specifically intended for use by alpha keypads only.
Functions Of The Keypad (cont’d) Fixed-Word Keypad Displays AWAY: STAY: INSTANT: BYPASS: NOT READY: READY: NO AC: AC: CHIME: BAT: ALARM: CHECK: FIRE: – 14 – All burglary zones, interior & perimeter, are armed. NO AC AWAY CHIME STAY Perimeter burglary zones, BAT ALARM INSTANT CHECK BYPASS such as windows & doors, are NOT READY FIRE armed. STYLE A Perimeter burglary zones armed and entry delay is NO AC AWAY turned off.
Entry/Exit Delays General Information Your system has preset time delays, known as exit delay and entry delay. Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection. If programmed, a slow beeping will sound throughout the exit delay period.
Security Codes & Authority Levels General Information At the time of installation, you were assigned an authority level and a personal four-digit security code, known only to you and yours. The security code must be entered when arming and disarming the system. The authority level defines the system functions that you can perform.
Security Codes & Authority Levels (cont’d) Authority Levels Authority levels define the system functions a particular user can perform. Depending on the authority assigned to you, there are certain system functions you may be prohibited from performing. In summary, there are six authority levels, each having certain system restrictions as shown below. Level 1 Master: Can perform all system functions in assigned partitions, and can add, delete or change Manager and Operator level users.
Security Codes & Authority Levels (cont’d) General Rules on Authority Levels and Changes • A user may not delete or change the user code of the SAME or HIGHER authority than which he is assigned. • A user may only ADD users to a LOWER authority level. • A user may assign access codes only to those partitions to which the user adding the code has access. (ex. a user with access to only partition 1 cannot assign codes in partition 2.
Security Codes & Authority Levels (cont’d) To Add a User IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones). CODE 1. Enter Master or Manager code and press the 8 key. 2. Enter the new user's 2-digit User Number (02-99). 3. Enter 4-digit security code for that user. The following prompts will appear. ADD NEW USER? 0 = NO , 1 = YES Enter 1 to add a new user code.
Security Codes & Authority Levels (cont’d) GLOBAL ARM ? 0 = NO , 1 = YES Press 1 (YES) if this user will be allowed to try to arm more than one partition at the same time. Press 0 if this user will arm only his assigned partition. PART.2 - SHOP? 0 = NO , 1 = YES The keypad now prompts for the user’s access to the next partition (see GOTO command). Again press 0 or 1.
Security Codes & Authority Levels (cont’d) whether or not this is a new user. Enter 0 to change the existing user's code to the code entered in step 3. USER 02 CHANGED SUCCESSFULLY The system will confirm that the change is allowed based on authorization level, and if so, will put the new code into effect. Note that if changing one’s own code, the system will prompt for the new code to be reentered. This prevents accidentally changing one's own code. To Delete a User CODE 1.
Accessing Other Partitions (GOTO Command and Global Arming) To Access Another Partition Each keypad is assigned a default partition for display purposes, and will show only that partition's information. But, if the user is authorized, a keypad in one partition can be used to perform system functions in other partitions by using the GOTO command. Note that only those partitions authorized and programmed by the installer can be accessed in this manner. To GOTO another partition: READY 1.
Accessing Other Partitions (cont’d) (GOTO Command and Global Arming) Master Keypad Operation A "Master" keypad is one that reflects the status of the entire system (Partitions 1-8) on its display. This is useful because it eliminates the need for a security officer in a building to have to "log-on" to various partitions from one partition's keypad to find out where an alarm has occurred.
Accessing Other Partitions (cont’d) (GOTO Command and Global Arming) FAULT 02 LOADING DOCK WINDOW Additional zone faults will be displayed one at a time. To display a new partition's status, press ✴ + [Partition No.]. This will display the status of the new partition. The "Armed" LED on a Master keypad will be lit only if all partitions have been armed successfully. The "Ready" LED will be lit only if all partitions are "ready to arm.
Checking For Open Zones Using the ✴ READY Key Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING section). Otherwise the keypad will display a "Not Ready" message. Using the READY key will display all zones that are faulted, making it easier for you to secure any open zones. To show faulted zones: DISARMED - PRESS ✴ TO SHOW FAULTS Note: Some keypads light a green LED when the system is ready.
Displaying All Zone Descriptors Using the ✴ READY Key The Alpha Keypads can also display all the zone descriptors that are programmed in your system. The abbreviated instructions for the READY key will appear first, followed by the zone descriptors. Displaying all descriptors is useful when you need to know the zone number of a particular zone, as when bypassing zones. The "Disarmed-Ready to arm" message must be displayed before zone descriptors can be displayed.
Bypassing Protection Zones Using the 6 BYPASS Key This key is used when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful. Note: The system will not allow fire or emergency zones to be bypassed.
Bypassing Protection Zones (cont’d) To use the Quick Bypass feature: BYPASS 1. Enter your security code and press 6 then press # . 2. BYPASS 07 FRONT UPSTAIRS BEDROOM Typical bypass message 3. DISARMED BYPASS READY TO ARM In a few moments, all open zones will be displayed along with the word BYPASS. Wait for these zones to be displayed before arming. Arming the system before bypassed zones are displayed eliminates all bypasses. Arm the system as usual when the keypad displays the "ready" to arm message.
Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use this key when you are staying home, but might expect someone to use the entrance door later. When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm will occur.
Arming Perimeter Only (With Entry Delay OFF) Using the 7 INSTANT Key Use this key when you are staying home and do not expect anyone to use the entrance door. When armed in INSTANT mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. The alarm will also sound immediately if anyone opens the entrance door. Close all perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section). INSTANT 1.
Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm. You may also reenter through the entrance door, but must disarm the system within the entry delay period or an alarm will occur.
Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when no one will be moving through protected interior areas. When armed in MAXIMUM mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises.
Disarming And Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See "SUMMARY OF AUDIBLE NOTIFICATION" section for information which will help you to distinguish between FIRE and BURGLARY alarm sounds. IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location.
Using The Keyswitch General Your system may be equipped with a keyswitch for use when arming and disarming. A red and green light on the keyswitch plate indicate the status of your system as follows: Green Light: Lights when the system is disarmed and ready to be armed (no open zones). If the system is disarmed and the green light is off, it indicates the system is not ready (one or more zones are open). Red Light: Lights when system is armed or memory of alarm exists.
Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the Keypad whenever a protected perimeter door or window is opened, and the Not Ready message will be displayed. Pressing the READY key will display the open protection points. Note that Chime mode can be activated only when the system is disarmed. 1. To turn Chime Mode on, enter the security code and press 9 .
Viewing Central Station Messages General Information Users of the system may periodically receive messages on their display screens from their monitoring agency or installer. When a message is waiting to be viewed, the message shown below will appear. MESSAGE. PRESS 0 FOR 5 SECS. 1. Press and hold down 0 key for 5 seconds. 2. The message could take up to four screens to display all the information available.
Panic Keys (For Manually Activating Silent And/Or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key combinations to manually activate panic functions. The functions that might be programmed are Silent Emergency, Audible Emergency, Personal Emergency, and Fire. See your installer for the function(s) that may have been programmed for your system. Active Panic Functions (Your installer should note which function(s) is active in your system.
Speed Key (Macros) General Information The "D" key can be used to activate a string of commands up to 16 keystrokes. These commands are known as a macro and are stored in the system's memory. Typical Speed Key functions include: • Seldom used but repeatable sequences. • Arming sequences that involve first bypassing certain zones before arming. • Relay activation sequences.
Speed Key (Macros) (cont’d) Executing Press and hold down the "D" key (about 2 seconds) until the following prompt appears: ENTER USER CODE ✴✴✴✴ Enter your user code. The defined speed key sequence will begin automatically. NOTE: When defining speed key sequences, do not use the [#] key to represent Quick Arming. The system uses the code entered at the prompt to initiate commands in a speed key sequence. The system interprets the use of the [#] key in a speed key sequence as its designated function only.
Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked using a keypad command. Ask your installer if this has been done in your system. To activate this command: Enter your security code and press 0 . The door will unlock for 2 seconds.
Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by using the #70 command from either a keypad or a telephone keypad (if 4285 VIP module is used). Ask your installer if this has been done in your system. To activate relays from a keypad, enter 4-digit security code + [#] +70. Follow the keypad prompts described below. To activate relays using a telephone and 4285 VIP module, first dial the 2-digit phone access code.
Using #70 Relay Menu Mode (cont’d) NN DEVICE IS OFF HIT THE "T" KEY Voice: "voice descriptor DEVICE nn ON/OFF. TO EXIT ENTER 00 NOW" From a keypad, press T to continue. The ENTER DEVICE NO. prompt will appear. From a telephone keypad, enter 00 to exit, or enter the next relay number to be programmed. The current on/off state of that relay will be annunciated as described above.
Using Schedules Delaying the Closing Time Your system's programmed schedules may automatically arm the system at a predetermined time. In the event a user must stay on the premises later than usual, users with master or manager authority levels can manually delay the automatic arming (closing) time up to 2 hours. To delay the closing time: 1. Enter your security code (master or manager authority levels only). 2. Press the # key, followed by 82. 3.
Using Schedules (cont’d) Before programming a temporary schedule, use a worksheet similar to the one below to plan your schedule. This will make it easier when actually programming the schedule. Arm/Disarm Windows Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM Mon Tue Wed Thu Fri Sat Sun Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered.
Using Schedules (cont’d) Press # to move to the next screen display without making changes. MON ARM WINDOW 07:45AM 08:45AM The cursor will be positioned on the tens of hours digit of the start time for the arm window. Repeat the previous steps to enter the start and stop time for Monday's arming window. TUE DISARM WIND. 07:45AM 08:45AM After the windows for that day have been completed, the system will prompt for disarm and arm time windows for the next day. Repeat the procedure for all days of the week.
Programming Device Timers General Information Device timers consist of an ON time & an OFF time, and selected days of the week in which they are active. There are up to 20 timers that can be used to control various devices, such as lights or appliances. Your installer will have programmed the appropriate devices into the system (up to 16 devices can be programmed). Each timer controls a single device (designated as an output number) that you select.
Programming Device Timers (cont’d) See your installer for device numbers. 00 ENTER OUTPUT# 00 Enter the desired output device number (116). As the number is entered, the device's description will appear. To delete a previously programmed timer, enter 00 as the output number. 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication.
Programming Device Timers (cont’d) the week progresses, the selected days are reset to the inactive state, unless the permanent option is selected (next screen prompt). When completed, press * to continue. 00 PERMANENT ? 0 = NO, 1 = YES 0 – 48 – Answering 1 (yes) means the system will continue executing this timer on a continuous basis. An answer of 0 means execute each day's output only once.
Testing The System (To Be Conducted Weekly) Using the 5 TEST Key The TEST key puts your system into Test mode, which allows each protection point to be checked for proper operation. 1. Disarm the system and close all protected windows, doors, etc. READY should be displayed. TEST 2. Enter your security code and press the 5 key. 3. The external sounder should sound for 3 seconds and then turn off. If the sounder does not sound, it may be due to dialer communication activity. Wait a few minutes and try again.
Testing The System Testing Your System 1. Open and close each protected door and window in turn and listen for three beeps. The identification of each faulted protection point should appear on the display. 2. Walk in front of any interior motion detectors (if used) and listen for three beeps as movement is detected. The identification of the detector should appear on the display when it is activated. 3.
Trouble Conditions Typical "Check" Displays The word CHECK on the Keypad's display, accompanied by a rapid "beeping" at the Keypad, indicates that there is a trouble condition in the system. To silence the beeping sound for "check" conditions, press any key. 1. A display of "CHECK" accompanied by a display of "CALL SERVICE" indicates that a problem exists with the system that eliminates some of the protection. CALL FOR SERVICE IMMEDIATELY.
Trouble Conditions (cont’d) Power Failure If the POWER indicator is off, operating power for the system has stopped and is inoperative. CALL FOR SERVICE IMMEDIATELY. If the POWER indicator is on, but the message "AC LOSS" is displayed, the Keypad is operating on battery power only. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. CALL FOR SERVICE IMMEDIATELY if AC power cannot be restored.
Fire Alarm System (If Installed) General Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the installed smoke and heat detectors will automatically send signals to your Control/Communicator, triggering a loud, interrupted sound from the Keypad. An interrupted sound will also be produced by optional exterior sounders. A FIRE message will appear at your Keypad and remain on until you silence the alarm. In Case Of Fire Alarm 1.
Fire Alarm System (If Installed) 3. If this does not remedy the problem, there may still be smoke in the detector. Clear it by fanning the detector for about 30 seconds. 4. When the problem has been corrected, clear the display by entering your code and pressing the OFF key.
Recommendations For Proper Protection THE FOLLOWING RECOMMENDATIONS FOR THE LOCATION OF FIRE AND BURGLARY DETECTION DEVICES HELP PROVIDE PROPER COVERAGE FOR THE PROTECTED PREMISES. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below.
Recommendations For Proper Protection (cont’d) ✪ KITCHEN ▲ DINING ✪ ✪ ✪ BEDROOM BEDROOM TV ROOM ■ ✪ ✪ LIVING ROOM BEDROOM ▲ KITCHEN ✪ DINING ■ LIVING ROOM ✪ ■ ✪ BDRM BDRM ✪ BEDROOM ✪ ▲ ■ Smoke Detectors for Minimum Protection ✪ Smoke Detectors for Additional Protection ▲ Heat-Activated Detectors ■ BEDROOM ✪ ■ ✪ BEDROOM TO BR BEDROOM ■ ▲ ▲ KTCHN .
Recommendations For Proper Protection (cont’d) Recommendations For Proper Intrusion Protection For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building.
Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants. PORCH M ET OO OS DR CL BE M M OO OO TH DR DR BA BE BE 2ND FLOOR N HE TC KI M OO DR BE BACK DOOR M OO TH DR BA BE 1ST FLOOR • • BACK • FRONT – 58 – 2. Determine two means of escape from each room.
Maintaining Your System Taking Care of Your System The components of your security system are designed to be as free of maintenance as possible. However, there are some things you can do to make sure that your system is in reliable working condition. 1. Test your system weekly. 2. Test the system after any alarm occurs (see TESTING THE SYSTEM).
Maintaining Your System (cont’d) meantime, the sensor(s) causing the low battery indication is still fully operational. Important: Use only batteries recommended by your installer as replacement. Silencing Low Battery Warning Tones at the Keypad The keypad’s warning tones can be silenced by performing an OFF sequence (code plus OFF key), but the Keypad's low battery message display will remain on as a reminder that you have a low battery condition in one or more of your sensors.
Quick Guide To System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [✱]. Display All Descriptors Arm System Press and hold [✱] for 5 seconds. Enter code. Press arming key desired(AWAY, STAY, INSTANT, MAXIMUM). Enter code. Press OFF [1]. Enter code. Press BYPASS [6]. Enter zone numbers to be bypassed (use 2-digit entries). Enter code. Press BYPASS [6]. Press [#]. Enter code. Press CHIME [9]. Enter code. To view faulted zones when system not ready.
Quick Guide To System Functions (cont’d) FUNCTION PROCEDURE COMMENTS Change a User's Code Enter master/manager code. Press CODE [8]. Enter user's 2-digit number. Enter new code for that user. Press 0 (No) at prompt. Enter master/manager code. Press CODE [8]. Enter user no. to be deleted. Enter master/manager code. Press 1 (Yes) at prompt. Press and hold any function key for at least 5 seconds. Master & Manager level users can change their own or other users' codes.
Summary Of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External LOUD, CONTINUOUS* Keypad & External ONE SHORT BEEP (not repeated) Keypad only FIRE ALARM FIRE is displayed; descriptor of zone in alarm is displayed. BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; descriptor of zone in alarm is also displayed. a. SYSTEM DISARM b. SYSTEM ARMING ATTEMPT WITH AN OPEN ZONE. c. BYPASS VERIFY ONE SHORT BEEP (once every 15 sec.
Glossary The following terms are used throughout the manual. ARM/DISARM: “Armed” simply means that the burglary portion of your system is turned ON and is in a state of readiness. “Disarmed” means that the burglary system is turned OFF, and must be rearmed to become operational. However, even in a “disarmed” state, “emergency” and “fire” portions of your system are still operational. KEYPAD: This is the area on your Keypad containing numbered pushbuttons similar to those on telephones or calculators.
UL NOTICE: This is a “GRADE A” system. “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT” This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.
“FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. This equipment uses the following jacks: An RJ31X is used to connect this equipment to the telephone network.
CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: • Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device. • Intrusion detectors (e.g.
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM (continued) • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms.
OWNER’S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner’s insurance carrier for possible premium credit. A. GENERAL INFORMATION: Insured’s Name and Address: Insurance Company: Policy No.: ADEMCO’s VISTA-50 Type of Alarm: Other ___________________________ Burglary Fire Installed by: Both Serviced by: Name Name Address Address B. NOTIFIES (Insert B = Burglary, F = Fire) Local Sounding Device Police Dept. Central Station Fire Dept.
OWNER’S INSURANCE PREMIUM CREDIT REQUEST (cont.) E. SMOKE DETECTOR LOCATIONS Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall F. BURGLARY DETECTING DEVICE LOCATIONS: Front Door Basement Door Rear Door All windows Interior locations All Exterior Doors 1st Floor Windows All Accessible Openings, Including Skylights, Air Conditioners and Vents G.
Index 4285 VIP Module .............................. 8, 41 97 Call Service ...................................... 52 AC .......................................................... 14 AC Loss.................................................. 52 Access Another Partition...................... 22 Access Door ........................................... 40 Add a User............................................. 19 Ademco Dealer ...................................... 52 Alarm........................................
Index (cont’d) Personal Emergency .............................37 Power .....................................................52 Quick Arming ........................................16 Quick Bypass.........................................27 Ready ...................................14, 25, 35, 53 Ready Key..............................................25 Relay Menu Mode .................................41 Replacing Batteries...............................59 Routine Care ........................................
ADEMCO ONE YEAR LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates (“Seller”), 165 Eileen Way, Syosset, New York 11791, warrants its security equipment (the “product”) to be free from defects in materials and workmanship for one year from date of original purchase, under normal use and service.
EVENT LOGGING PROCEDURES General Information To Display The Event Log The system has the ability to record various events in a history log wherein each event is recorded in one of five categories (listed below), with the time and date of its occurrence. The Event Log holds up to 224 events, with the oldest event being replaced by the logging of any new event after the log is full.
EVENT LOGGING PROCEDURES (continued) 4. Use the [3] & [1] keys (for next and previous categories respectively) to display the categories of events. Press [8] to select a category and display the first event. Press [8] again for each subsequent event. Shows burglary alarm occurred in zone 3 (C03) of partition 1 (P1), at 12:02AM on January 1.