Specifications
5-80 Menus and Commands
600561-A
and can not be changed. The Parity : Now
parameter indicates if the SCSI parity is enabled
(Yes, No). If parity is disabled, the retries parameter
is ignored.
The value of the Retries : Now parameter in the
Parity Dialog is supplied by the library firmware
and can not be changed. The Retries : Now
parameter indicates the current number of retries
(000 .. 255) allowed when a SCSI parity error is
detected.
Step 2 Repeat Step 1 for all of the parameters in the list.
If
Y
is selected for the Accept parameter value, the screen
updates to reflect the changes. Otherwise, the changed
parameters continue to display but no action is taken.
Ports Dialog
When
Ports
is selected, the Ports Dialog is displayed. See
Figure 5-94. This option indicates the current SCSI bus type
and usage.
Figure 5-94 Ports Screen
Parameters Values
Bus 0 : Installed YES indicates the port is active
NO indicates the port is not
active.
Bus 0 : Type HVD indicates the bus is high
voltage differential
LVD indicates the bus is low
voltage differential
SE indicates the bus is single
ended.
Bus 1 : Installed YES indicates the port is active
NO indicates the bus is not
active.
INSTALLED TYPE
Bus 0: YES HVD
Bus 1: NO -