Specifications
Utils Menu Selection 5-119
01 Aug 2000
column
The fifth field indicates the row
of the column. (01 .. 12 for half
inch and DLT coordinates)
(01 .. 18 for 8mm coordinates)
Element Indicates the element number
which corresponds with the
coordinate parameter
Accept Y to accept changes
N to reject changes
Press the button to confirm the changes.
Step 2 Repeat Step 1 for all of the parameter in the list.
If
Y
is selected for the Accept parameter value, the
Element Dialog appears. See Figure 5-130. Otherwise,
the changed actions continue to display but no action is
taken.
Figure 5-130 Element Dialog
Step 3 Press the button to select the current parameter
default value and move to the next parameter.
— or —
Press the button or the button to toggle the
parameter values.
Parameters Values
Coord The first field indicates the
type of cell (I for I/E Station, D
for Drive, S for Storage cell)
The second field indicates the
module number which can be
modified if expansion modules
are present (1 .. 4)
The third field indicates the
storage cell section (1 .. 4),
Enter TARGET
Coord: D 01 1< A 01
OR Element:01200
Accept : N