Specifications

6-6 Processing Media
600561-A
Direct Removal from the Control or
Expansion Module
There are two levels of access control. The first is a mechanical
lock which is manipulated by the key. The second is password
protection which is invoked by either the host SCSI Mode
Select command, LCD Page Security option, or through the
Security option on the Operator panel.
To directly remove media, follow this procedure.
If enabled, all locks must be disabled before the procedure
will succeed.
Step 1 If the password option is enabled, enter the
password.
Step 2 Use the Operator panel to place the library into the
NOTREADY state. Refer to
Mode Dialog Selection
on
page 5-9.
The accessor completes any current task and returns to
the home position.
Step 3 Using the key, unlock and open the library door.
Step 4 Remove the cartridge from the desired storage cell.
Step 5 Close and lock the door.
Step 6 Place the library in the READY state. Refer to
Mode
Dialog Selection
on page 5-9.
Step 7 If Auto-Inventory is disabled, execute a SCSI
INITIALIZE ELEMENT STATUS or a library
Inventory command.
Processing Media
Each tape cartridge in the Scalar 1000 must have an external
label that is operator and machine readable to identify the
barcode number (BC). A BC must use only uppercase letters
A-Z and/or numeric values 0-9. The Scalar 1000 currently
supports Code 39 and Storage Technology type barcode
labels.
STATIC
SENSITIVE
Caution