Specifications
Service Action Codes 7-5
01 Aug 2000
13 Cannot read Cartridge Barcode label.
Check Cartridge label to ensure that it meets specifications and is installed
properly. Look for the following:
• a damaged or dirty label
• Library not configured for correct media mode
• too short (less than 5 characters) or too long (more than 16 characters) label.
The cell in question is displayed with the Service Action Code. Run the Start
Option from the Operator Panel to retrieve this information. Refer to
Service
Menu Selection
on page 5-130.
If the problem is not corrected or persists, contact ATAC.
14 Cannot read the Serial Number label during a Teach operation.
Check the Serial Number label to ensure that it is installed properly and not
damaged or dirty.
The Serial Number label is located on the lower right corner of the first 5x10 or
5x15 storage array in the Control Module. The Serial Number label contains a
barcode and readable serial number. Example: 201100031
If the problem is not corrected or persists, contact ATAC.
30 A fatal error is detected in SCSI Port 0.
Verify that the library Port 0 is configured by using the Operator Panel Main
Menu.
If the problem is not corrected or persists, contact ATAC.
31 A fatal error is detected in SCSI Port 1.
Verify the Library SCSI Port 1 is properly configured by using the Operator
Panel Main Menu.
If the problem is not corrected or persists, contact ATAC.
32 Wrong SCSI bus connection is detected.
Verify that the Host SCSI bus is the same type as the Library SCSI Adapter card
in Port 0 by using the Operator Panel Main Menu.
If the problem is not corrected or persists, contact ATAC.
Table 7-1
SAC Reporting
Reported
SAC
Perform these actions