Specifications

7-6 Error Messages
600561-A
33 Wrong SCSI bus connection is detected.
Verify that the Host SCSI bus is the same type as the library SCSI Adapter card
by using the Operator Panel Main Menu.
If the problem is not corrected or persists, contact ATAC.
40 The Library Aisle power cannot be enabled.
Check that all doors are closed.
Contact ATAC.
50 A cartridge is not properly seated in the storage cell.
Check to ensure that the cartridge in question is properly installed in its storage
cell.
Check cartridge label to ensure that it is within specifications and is installed
properly and is not damaged or dirty.
Reteach the library using the Operator panel.
If the problem is not corrected or persists, contact ATAC.
60 Cannot complete Lock/Unlock I/E station commands.
Run the Lock Diagnostics from the Operator Panel to check for mechanical
binding.
If the problem is not corrected or persists, contact ATAC.
71 Failures detected in the Gripper Assembly Finger Close operation.
Run Teach Current.
If the problem is not corrected or persists, contact ATAC.
72 A Get command is issued but the sensor indicated that a cartridge is already
present in the Gripper Assembly.
Look into the Gripper Assembly and see if a cartridge is present.
If a cartridge is found:
Perform the actions in Service Action Code 02.
If no cartridge is found in the Gripper Assembly:
Contact ATAC.
Table 7-1
SAC Reporting
Reported
SAC
Perform these actions