Specifications

Service Action Codes 7-7
01 Aug 2000
74 A Get command is issued but the sensor indicated that the location is empty.
Look into the location (cell or drive) and see if a cartridge is present.
If no cartridge is found in this location:
Perform the actions in Service Action Code 02.
If a cartridge is found:
Contact ATAC.
78 A Put command is issued but the sensor indicated that the cartridge is not
present in the Gripper Assembly.
Look into the Gripper Assembly and see if a cartridge is present.
If a cartridge is found:
Contact ATAC.
If no cartridge is found in the Gripper Assembly:
Perform the actions in Service Action Code 02.
79 Failures detected in putting a cartridge into a DLT tape drive.
Check the DLT tape drive to ensure that it is powered On and working
properly. Refer to the DLT Maintenance Manual for any DLT drive problem.
If the problem is not corrected or persists, contact ATAC.
7C Failures detected in the Gripper Assembly Reach operation.
Check for obstruction in the cell. Obstruction can be an unlabeled cartridge or a
cartridge in the cell during a Put operation.
If the problem is not corrected or persists, contact ATAC.
7D Failures detected while getting a cartridge from the Tape Drive.
Check for a tape in the Tape drive.
If the problem is not corrected or persists, contact ATAC.
83 The Locate Fiducial Command failed with no target found. This failure
happens most likely during an initial installation of the Library Subsystem.
Check and clean all Teach Fiducial labels.
Run Teach New from the Operator panel. Check that the scan beam is
positioned directly in front of the label.
If the problem is not corrected or persists, contact ATAC.
Table 7-1
SAC Reporting
Reported
SAC
Perform these actions