E5 The SCSI bus connected to Library Port 0 is not properly terminated.
Check the SCSI bus for termination.
If the problem is not corrected or persists, contact ATAC.
E6 The SCSI bus connected to Library Port 1 is not properly terminated.
Check the SCSI bus for termination.
If the problem is not corrected or persists, contact ATAC.
E7 The Gripper Assembly detected that a cartridge is not present in the Grip
fingers. The cartridge may have been dropped or the Get operation was not
successful.
Look to see if the cartridge is in the storage cell, in the base of the Gripper
Assembly or on the floor of the Library. Recover the cartridge and re-inventory
the Library.
E8 During an accessor more to put a cartridge after a successful Get command,
the Gripper Assembly detected that the cartridge is no longer present in the
Grip fingers.
Look at the Gripper Assembly base or the floor of the Library to see if a
cartridge can be located.
EB A battery low condition was detected in the Remote Management Unit
(RMU)
Replace the 9V battery in the RMU.
FOR ANY
OTHER
SAC
Service may be required.
Contact ATAC and report the SAC.