Specifications
4-38 Description
600561-A
Scalar 1000 Shutdown
The Scalar 1000 may be shut down normally or by the
Emergency Shutdown method.
Use the method described in Emergency Shutdown in cases
of emergency only.
Normal Shutdown
To properly shut down the Scalar 1000 follow the procedure.
With the RMU installed, power up must be delayed by at
least 10 seconds after a power down condition to allow the
RMU to properly shutdown.
Step 1 If necessary, use the button to return to the
Main Menu. The selector defaults to the Mode
selection. Press the button. From the Mode
screen, use the button to select the Shutdown
mode.
Press the button.
The
*
moves to the Shutdown mode and the state
automatically changes to Shutdown. The Accessor
completes the current task and returns to the home
position. The reboot message appears. See Figure 4-16.
Figure 4-16 Reboot Screen
Step 2 Locate the Main Power Switch at the lower right
corner in the back panel door of the Control
Module.
Step 3 Push in the bottom of the rocker Main Power
Switch.
Power is removed from the Scalar 1000 Control Module.
Attentio
n
Caution
The library may now
be rebooted