MEASUREMENT FOUNDATION Operating manual Line laser level ADA CUBE Manufacturer: ADAINSTRUMENTS Address: WWW.ADAINSTRUMENTS.
CUBE Table of contents 1. Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4. Change of batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 5. Laser lines. . . . . . . . . .
CUBE Kit Cross line laser, batteries, operating manual, universal mount (optional), a tripod (optional), laser glasses (optional), сarrying case (optional). Manufacturer may modify complete set without notice. Application Cross Line Laser projects visible laser planes. It is used for determination height, making horizontal and vertical planes.
CUBE Change of batteries Open battery compartment. Put in 2xAA A Alkaline batteries. Take care to correct polarity. Close battery compartment. ATTENTION: If you are not going to use instrument for a long time, take out batteries.
CUBE Features 2 1 1. 2. 3. 4.
CUBE Operation Place the instrument on the working surface or mount it on the tripod/pillar or wall mount. Switch on the instrument: turn the compensator switch (3) to the position “ON”. When enabled, the vertical and horizontal plane projected constantly. Visual alarm (blinking line) and audible signal indicate that the device was not installed within the compensation range ± 3 º. To properly work align the unit in a horizontal plane.
CUBE APPLICATION DEMONSTRATION For more information you can visit our website www.adainstruments.
CUBE To check the accuracy of line laser level To check the accuracy of line laser level (slope of plane) Set up the instrument between two walls, the distance is 5 m.Turn on the Cross Line Laser and mark the point of cross laser line on the wall. Set up the instrument 0,5-0,7m away from the wall and make, as described above, the same masrks. If the difference {a1-b2} and {b1-b2} is less then the value of “accuracy” (see spesifications), there is no need in calibration.
CUBE To check level Choose a wall and set laser 5m away from the wall. Turn on the laser and cross laser line is marked A on the wall. Find another point M on the horizontal line, the distance is around 2.5m. Swivel the laser, and another cross point of cross laser line is marked B. Please note the distance of B to A should be 5m. Measure the distance between M to cross laser lune, if the difference is over 3mm, the laser is out of calibration, please contact with seller to calibrate the laser.
CUBE B, along the vertical laser line on the wall and measure the distance 3m from point B to another point C. Point C must be on the vertical laser line, it means the height of C point is 3m. Measure the distance from point A to point C, if the distance is over 2 mm, please, contact with seller to calibrate the laser. Care and cleaning Please handle measuring instrument with care. Clean with soft cloth only after any use. If necessary damp cloth with some water.
CUBE • • After instrument has been dropped or hit. Please check the accuracy. Large fluctuation of temperature: if instrument will be used in cold areas after it has been stored in warm areas (or the other way round) please wait some minutes before carrying out measurements. • Electromagnetic acceptability (EMC) • • It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems); will be disturbed by other instruments (e.g.
CUBE Laser classification The instrument is a laser class 2 laser product accortding to DIN IEC 60825-1:2007. It is allowed to use unit without further safety precautions. Safety instructions Please follow up instructions given in operators’ manual. Do not stare into beam. Laser beam can lead to eye injury (even from greater distances). Do not aim laser beam at persons or animals. The laser plane should be set up above eye level of persons. Use the instrument for measuring jobs only.
CUBE In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to this product if it has been misused, abused or altered. Withiut limiting the foregoing, leakage of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or abuse. Exceptions from responsibility The user of this product is expected to follow the instructions given in operators’ manual.
WARRANTY DOESN’T EXTEND TO FOLLOWING CASES: 1. If the standard or serial product number will be changed, erased, removed or wil be unreadable. 2. Periodic maintenance, repair or changing parts as a result of their normal runout. 3. All adaptations and modifications with the purpose of improvement and expansion of normal sphere of product application, mentioned in the service instruction, without tentative written agreement of the expert provider. 4.
WARRANTY CARD Name and model of the product ________________________________________________ Serial number ________________date of sale_______________________ Name of commercial organization _____________________stamp of commercial organization Warranty period for the instrument explotation is 24 months after the date of original retail purchase. During this warranty period the owner of the product has the right for free repair of his instrument in case of manufacturing defects.
Certificate of acceptance and sale __________________________________________________________________________ __________________________________________________________________________ ___________________________________________________________№_____________ name and model of the instrument Corresponds to ______________________________________________________________ designation of standard and technical requirements Data of issue _______________________________________________________________ Stamp of qual