To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
Do not spill water or other liquids into or on to your unit.
Do not attempt to operate this unit if the power cord has been
frayed or broken. Do not attempt to remove or break o the ground
prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user
serviceable parts inside.
Never operate this unit when it’s cover is removed.
Never plug this unit in to a dimmer pack
Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
This unit is intended for indoor use only, use of this product out`
doors voids all warranties.
During long periods of non-use, disconnect the unit’s main power.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by
t he manufacturer. See page 27 for cleaning details.
Heat -The appliance should be situated away from heat sources
such as radiators, heat registers, stoves, or other appliances (inclu-
d ing amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
C. The appliance has been exposed to rain or water.
D. The appliance does not appear to operate normally or exhibits a
marked change in performance.
Mega TRIPAR Profile Plus Trouble Shooting
Listed below are a few common problems the user may encounter,
with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are
wired correctly (pin 3 is “hot”; on some other DMX devices
pin 2 may be ‘hot’). Also, check that all cables are connected
to the right connectors; it does matter which way the inputs
and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
2. Make sure that Sound Active mode is activated.
Mega TRIPAR Profile Plus Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses must be carried out periodically to optimize light
output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging
the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
Disconnect the unit from its power source. Remove the power cord
from the unit. Once the cord has been removed, you will find that the
fuse holder is located inside the power socket. Insert a flat-head screw
driver into the power socket and gently pry out the fuse holder. Remove
the bad fuse and replace with a new one. The fuse holder also has a
holder for a spare fuse.
Mega TRIPAR Profile Plus Fuse Replacement
With this feature you can connect the xtures to one another
using the IEC input and output sockets. The quantity that can be
connected is 30 xtures maximum. After 30 xtures you will need
to use a new power outlet. They must be the same xtures. DO
NOT mix xtures.
Mega TRIPAR Profile Plus Power Cord Daisy Chain