PLATINUM BEAM 5R KEEP THIS MANUAL FOR FUTURE NEEDS
XM485-V1.
Thank you for your patronage. We are confident that our excellent products and service can satisfy you. For your own safety, please read this user manual carefully before installing the device. In order to install , operate, and maintain the lighting safety and correctly. We suggest that the installation and operation should be done by the verified technician and follow the instruction strictly.
·Stepless frost, 0%~100% linear change frost ·Strobe/shutter: High speed shutter, 0-13 Hz or random strobe ·Control board with full color LCD graphic display and touch-keyboard ·Auto-program: 7 pre-built programs can be selected.
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Important: Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.
GENERAL GUIDELINES This device is a lighting effect for professional use on stages, in discotheques, theatres, etc., the device was designed for indoor use only. This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual. Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure that the device will serve you for a long time without defects. Do not shake the device.
Before replacing the lamp let the lamp cool down, because during operation, the lamp can reach very high temperature. During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal. Do not install lamps with a higher wattage. They generate higher temperatures than which the device was designed for.
weight for 1 hour without any harming deformation. The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope. Never stand directly below the device when mounting, removing or servicing the fixture. The operator has to make sure the safety relating and machine technical installations are approved by an expert before taking the device into operation for the first time. These installations have to be approved by a skilled person once a year.
Installation via the Omega holders a) Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the Ф13 hole in the middle of the bracket. b) Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of the device. Tighten the quick-lock fasteners fully clockwise. c) Install the second Omega holder. d) Pull the safety-rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot.
Address 1 Address 14 Address27 DMX-512 connection with DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise.
to 1, the second unit to 14(13 + 1), the third to 27 (13 + 14), and so on. Control Board The Control Board offers several features: you can simply set the starting address , run the pre-programmed program or make a reset. The main menu is accessed by pressing the menu by pressing the -button , -button until the display starts flashing. Browse through the -button , -button or -button. Press the Enter-button in order to select the desired menu.
Temperature Info Head Temperature Software Version Ver1.0…… XXX℃/℉ Temperature in the head Software version of each IC Lamp On or Off ON/OFF La Automatic La-On ON/OFF mp Lamp On Via DMX ON/OFF Con Lamp Off Via DMX ON/OFF trol Lamp On at Temp. 20~79℃,55℃ /68~174℉ 131℉ Lamp Off at Temp.
rs Mo de Set Edit User Mode Max Channel = XX PAN = CH01 Preset User modes : Select Programs Edit Program Edit Pro gra Edit Scenes m Rec.
mode. Each slave setting will have a different function for a dynamic lightshow without a controller. Auto Program This function allows the internal programs to run in either stand-alone or master/ salve mode. In “Master” mode the fixture will send DMX data to other fixtures connect via the DMX chain. In “Alone” mode the fixture will operate as a single fixture. The program for this mode is selected in the “Select program” section of the control menu. You can set the number of steps under “Edit program”.
counter should be reset after every lamp change. Lamp Off Time This function displays the running time of the lamp from the last power on. The display shows “XXXX”, where “XXXX” represents the number of hours the lamp has been running since it was last struck. This counter is automatically reset after every power-on. Timer Password Use this function to enter the “Clear Last Run” password. Password is “038” Clear Last Run This function will allow the “Last Run Hours” function be cleared and reset.
Lamp Control: Lamp On or Off This function allows manual control of the lamp power via the on-board system menu. • Select “ON” if you wish to strike the lamp or “OFF” to switch it off. • Press “ENTER” to confirm. • Press the Mode/Esc-button to return to the main menu. Automatic La-On When in the “ON” position, this function will automatically turn the lamp on when power is applied to the fixture Lamp On Via DMX When engaged, this function will allow the lamp to be switched “on” via a DMX controller.
Personality: Status setting Address via DMX - This function allows the DMX address to remotely be adjusted from a DMX console. This setting requires special settings for both the controller and the fixture. RDMX is on by default. For operational instructions please see Section 10/Page 35 of this manual “Remote DMX addressing.” No DMX Status – This function dictates how the fixture will function if it looses DMX signal during normal operation.
includes original Design Spot 250s. There are 3 different mode variations; Speed 1 (Default): Slower than the original Design Spot 250 for smoother, more precise movements. Speed 2: Pan and Tilt speeds are identical to the first generation Design Spot 250. Speed 3: includes a faster Pan speed. Pan speed is 0.5 seconds faster than original DS-250. Tilt speed will be the same as speed 2. Mic Sensitivity – This function makes the internal microphone more or less sensitive to sound.
function is disabled as default. Key Lock – This function allows you to lock the keys on the display to prevent menu tampering. With this function you can activate the automatic keylock function. If this function is activated, the keys will be automatically locked in 15 seconds from the last command. In order to deactivate or temporarily deactivate the keylock function, press the Mode/Esc Button for 3 seconds to regain access to the menu commands.
Effect Adjust: Test Channel – This menu function allows the user to select each individual fixture channel and test it’s function independently from the control board. Lamp adjustment (manual control) – This function readies the fixture for lamp optimization in a simple single step procedure. This function will center the pan and tilt motors and at the same time open the shutter and bring the dimmer to 100%.
external DMX controller. For detailed instructions on how to complete this task please see Section 12/ Page 39. Select program – This function allows the user to select one of ten of the user defined built-in programs. This program is then accessed in “Function Mode” under “Program Run.” Edit program – This function allows the user to edit the built-in programs.
INSTRUCTIONS ON USE: DMX channel´s functions and their values (16 DMX channels): Mode/Channel St Ba Ex 1 1 1 2 3 2 2 4 5 3 4 3 5 6 6 4 7 Value 0-255 0-255 0-255 0-255 0-9 10-19 20-29 30-39 40-49 50-59 60-69 70-79 80-89 90-99 100-109 110-119 120-127 128-189 190-193 194-255 0-255 0-9 10-19 20-29 30-39 40-49 50-59 60-69 70-79 80-89 90-104 105-119 Function PAN Movement 8bit : Pan Movement By 360/540 Pan Fine 16bit Fine control of Pan movement TILT Movement 8bit : Tilt Movement By 270 Tilt Fi
120-134 135-149 150-164 165-179 180-194 195-209 210-255 7 5 8 9 8 9 6 7 10 11 0-127 128-189 190-193 194-255 0-255 0-3 4-63 64-67 68-127 128-135 136-143 144-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 0-31 32-63 64-95 96-127 128-159 160-191 192-223 224-255 Rot. gobo 3 shake Rot. gobo 4 shake Rot. gobo 5 shake Rot. gobo 6 shake Rot. gobo 7 shake Rot. gobo 8 shake Rot. gobo wheel cont.
10 8 12 13 11 12 13 9 10 11 14 15 16 0-255 0-255 0-127 128-255 0-225 226-235 236-245 246-255 0-19 20-29 30-39 40-59 60-79 80-84 85-87 88-90 91-93 94-96 97-99 100-119 120-139 140-159 160-179 180-199 200-219 220-239 240-255 Dimmer intensity: Intensity 0 to 100% Fine Dimmer intensity: Dimmer intensity fine Frost: Disable frost Enable frost Speed Pan/Tilt movement: max to min speed blackout by movement blackout by all wheel changing no function Lamp on/off, reset, internal programs: colour change n
some error in channel 1. If there are some errors on channel 1, channel 5, channel 6 at the same time, you may see the error message “Err channel is Color wheel”, “Err channel is Pan movement”, “Err channel is Tilt movement” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture remain error message after performing reset more than 2 times, only the channels which have errors can not work properly, others can work as usual.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents. There are no serviceable parts inside the device except for the lamp. Please refer to the instructions under “Installation instructions”. Should you need any spare parts, please order genuine parts from your local dealer. TECHNICAL SPECIFICATIONS Power supply: AC 100V-240V~, 50Hz/60Hz Power consumption: 350W Packing dimensions: 53.5 x 42 x 41 cm Net weight: 9.