3.6 Switching Tacking On/Off
By pressing this key tacking is switched on and off.
If the LED above the key is lit then tacking is switched on.
CAUTION !
With 1.4 mm stitch length in stitch condensation
tacking is generally switched off.
3.7 Selecting the Closing Order of the Flap Clamps
With this key the order of the closing of the flap clamps can be set.
In sewing programs P07 to P12 the order of the closing of the flap
clamps cannot be set.
Operating the key switches between four possibilities.
The order is shown by the two LEDs above the key:
Both LEDs lit:
The flap clamps close at the same time.
Only the left LED is lit:
First the left flap clamp closes, then the right.
Only the right LED is lit:
First the right flap clamp closes, then the left.
Both LEDs are off:
Operation without flap clamps (optimally timed procedure).
The timing for the opening of the flap clamps in the feed area is
established by the setting of the preselector switch b417.6 inside the
controls (see "Internal Switches"):
In the
OFF
setting the flap clamps open after the transport clasp
lowers.
In the
ON
setting the flap clamps open after the folder lowers.
3.8 Switching the Corner and Center Knives On/Off
With this key the corner knives or the center and corner knives can be
switched on and off.
In sewing programs P07 to P12 the corner and the center knives
cannot be switched off.
Operating the key switches between three possibilities.
The different settings are shown by the two LEDs above the key:
Both LEDs are lit:
Corner and center knives are switched on.
Only the right LED is lit:
The corner knives are switched off.
Both LEDs are off:
All knives are switched off.
11