Turn on main switch.
"
<---REF
" appears in the lower display line.
–
Step back on the left pedal.
The transport clasps are raised.
The transport carriage runs to its rear position.
–
The display signals start readiness by showing the current
parameters (see display example 1).
The settings correspond to the last settings selected before the
machine was turned off.
–
Set the "
Program
" switch to "
01
".
–
Press the "
STOP
" key.
The program is activated.
–
By tapping the left pedal bring the carriage return out of the hold
position, switch on the feed procedure and start.
–
By stepping back on the left pedal during the feed procedure the
previous steps can be activated again.
–
By stepping back on the left pedal the sewing process can be
interrupted after starting.
–
When the sewing unit is equipped with a right pedal this activates
the holder and the vacuum.
When the sewing unit is equipped with a knee switch this operates
the vacuum.
8.2 Sewing of Dual Piping with Automatic Carriage Return
–
Set the "
Program
" switch to "
02
".
–
Press the "
STOP
" key.
The program is activated.
In contrast to P01:
–
After stacking the transport clasps are automatically run back to
the feed area.
8.3 Sewing of Dual Piping with Material Return
–
Set the "
Program
" switch to "
03
".
–
Press the "
STOP
" key.
The program is activated.
In contrast to P01:
–
There is no stacking after sewing.
–
The material is transported back to the feed area by the transport
clasps.