Operating instructions

12.3 Error Messages
Display Explanation Remedy
DISP-Err
ERROR 0
ERROR 2
ERROR 3
ERROR 4
ERROR 5
ERROR 6
ERROR 7
ERROR 8
ERROR 9
ERR B..
kein SIO
ERR
AMP ERR
SMC ERR
LINK ERR
XCOU ERR
SCOU ERR
EPRO ERR
Display error when switching on
RAM error in P59
Error in reading the front panel elements
Program switch defective
Regulator card for sewing drive defective
Short voltage drops in mains
Timer 1 defective
Timer 2 defective
Timer 3 defective
Timer 4 defective
Error in reading input elements:
Defective or falsely adjusted limit
switches (no lower stroke) or proximity
switches are shown in the display with
their circuit diagram designation (e.g.
"ERR B31")
Controls have no SIO module
Interruption in the SIO send/receive loop
Error in step motor output
Step motor controller defective
Error in the transmission to the step
motor controller
Counter module for cycle counting on
step motor card defective
Counter module for cycle generation on
step motor card defective
EPROM on step motor card defective
Call factory service dept.
Check front panel elements
Replace program switch
Replace regulator card
Stabilize voltage supply
Call factory service dept.
Call factory service dept.
Call factory service dept.
Call factory service dept.
Replace defective switch,
Reset switch
Press STOP key
Press STOP key
Check LED’s on the step motor card
Replace step motor card
Replace step motor card
Replace step motor card
Replace step motor card
Replace step motor card
40