13. Step Motor Output
13.1 Programing Switches on the Front
Caution Current !
The three gravity switches are not to be adjusted when under current.
Before adjustment the main switch must be turned off.
–
The three gravity switches for step count and current reduction
must be open.
–
The dial must be in position 
C
.
13.2 Displays on the Front
The five LEDs on the step motor card show operating status and
malfunctions.
LED 1 (green)
Readiness
lit in as far as there is no malfunction
LED 2 (red)
Short circuit
lit with a short circuit between two motor phases
LED 3 (red):
Excess temperature
lit with a heat sink temperature > 75°
LED 4 (red)
Overvoltage
lit with operating voltages > 140 V VDC
(in braking operation)
LED 5 (red)
Undervoltage
lit with operating voltages < 80 V VDC
The step motor runs only when the is no fault in the step motor output.
A fault is displayed as follows:
–
The motor is switched currentless.
The green LED 1 goes out.
–
The fault is shown in that the appropriate red
LED 2 - 5 is lit.
After the malfunction is corrected the malfunction indicator is is
turned off by switching the main switch off and on.