Operating instructions

13. Step Motor Output
13.1 Programing Switches on the Front
Caution Current !
The three gravity switches are not to be adjusted when under current.
Before adjustment the main switch must be turned off.
The three gravity switches for step count and current reduction
must be open.
The dial must be in position
C
.
13.2 Displays on the Front
The five LEDs on the step motor card show operating status and
malfunctions.
LED 1 (green)
Readiness
lit in as far as there is no malfunction
LED 2 (red)
Short circuit
lit with a short circuit between two motor phases
LED 3 (red):
Excess temperature
lit with a heat sink temperature > 75°
LED 4 (red)
Overvoltage
lit with operating voltages > 140 V VDC
(in braking operation)
LED 5 (red)
Undervoltage
lit with operating voltages < 80 V VDC
The step motor runs only when the is no fault in the step motor output.
A fault is displayed as follows:
The motor is switched currentless.
The green LED 1 goes out.
The fault is shown in that the appropriate red
LED 2 - 5 is lit.
After the malfunction is corrected the malfunction indicator is is
turned off by switching the main switch off and on.
41