Instruction manual
  - DA321G5321 
- 17 - 
Setting the reference position on the control 
  Input code number and select parameter 170! 
  Press the E key 
 
Display 
Sr1 
  Press the >> key 
 
Display 
P o (character o rotating) 
Turn handwheel until rotating character 
o goes off on the display. 
 
Display 
P 
  By turning the handwheel, set the 
needle to the bottom dead center or the 
needle point to the height of the needle 
plate in the direction of rotation of the 
motor shaft, while needle is moving 
downward. 
 
Configuration of the zero point of the machine 
  Press the P key once 
 
actual parameter number is displayed 
  Press the P key twice 
 
Exit programming at the technician level. 
Setting the reference position on the V810 control panel 
  Input code number and select parameter 170! 
  Press the E key 
 
Display 
Sr [o] 
  Press the >> key 
 
Display 
PoS0 o (character o rotating) 
Turn handwheel until rotating character 
o goes off on the display. 
 
Display 
PoS0 
  Set the needle to the bottom dead 
center by turning the handwheel. 
 
Configuration of the zero point of the machine 
  Press the P key once 
 
actual parameter number is displayed 
  Press the P key twice 
 
Exit programming at the technician level. 
Setting the reference position on the V820/850 control panel 
  Input code number and select parameter 170! 
  Press the E key 
 
Display 
F-170 Sr1 [o] 
  Press the >> key 
 
Display 
PoS0 o (character o rotating) 
Turn handwheel until rotating character 
o goes off on the display. 
 
Display 
PoS0 
  Set the needle to the bottom dead 
center by turning the handwheel. 
 
Configuration of the zero point of the machine 
  Press the P key once 
 
actual parameter number is displayed 
  Press the P key twice 
 
Exit programming at the technician level. 
If error message A3 (reference position not set) appears, repeat the above setting sequence! 
5.8.2  Setting the Positions on the Control (Parameter 270 = 0 or 6) 
This setting must be set if no reference position was configured or the settings should be changed. 
  Input code number and select parameter 171. 
  Press the E key 
 
[o] is displayed 
  Press the >> key 
 
P1E is displayed; set "position 1 On" on the handwheel 
  Press the E key 
 
P2E is displayed; set "position 2 On" on the handwheel 
  Press the E key 
 
P1A is displayed; set "position 1 Off" on the handwheel 
  Press the E key 
 
P2A is displayed; set "position 2 Off" on the handwheel 
  Press the P key twice 
 
Exit programming at the technician level. 
*) During turning, the position information is deleted and the angle of the position displayed in degrees 
5.8.3  Setting the Positions on the V810 Control Panel (Parameter 270 = 0 or 6) 
This setting must be set if no reference position was configured or the settings should be changed. 
  Call parameter 188! 
E 
Press the E key! 
 
F – 1 7 1 
F2 
Press the F2 key! Actual display. 
 
  [ o ] 