Instruction manual

- DA321G5321
- 21 -
If parameter 139 = 1, the V810/820 display shows the following information:
V810
V820/V850
During operation:
The actual speed
Example: 2350 revolutions per minute
2350
2350
At stop in the seam:
The stop indication
StoP
StoP
At standstill after trimming:
On the V810, indication of the type of control
On the V820/V850, indication of the set maximum speed
and the type of control
Example: 3300 revolutions per minute and type of control
DA321G
dA321G
3300 dA321G
5.15 Operating Hours Counter
Function with or without control panel
Parameter
Acoustic Signal
Service routine for total operating hours
Service routine for operating hours before service
Input of operating hours before service
Selection of the output for flashing if the time until service is exceeded.
(AkS)
(Sr6)
(Sr7)
(Sr)
(oSe)
127
176
177
146
147
The integrated operating hours counter records the time of motor operation. Downtimes are not recorded. Time
recording accuracy is 1ms. There are two ways of operating hours counting.
1. Basic operating hours counting:
217 = 0
Operational mode: Operating hours counting
2. Service Hours Monitoring:
146 = >0
Operational mode: Number of operating hours before the next service.
Input of operating hours before the next service.
This value is compared to the operating hours counter.
The hours are programmed in steps of 10, i. e. the lowest display of 001 corresponds to 10 hours
(e. g. 055 = 550 hours).
When the set number of operating hours are reached, the message "C1" will show on the display
after each trimming operation. In addition, the speed indicator blinks on the control or on the
V820/V850 control panel during operation or after drive standstill.
Moreover, an acoustic signal is emitted when using a control panel if parameter 127 = 1.
If parameter 147=11, output M11 (socket ST2/31) is prepared for displaying the reached number of
pre-selected operating hours. Upon reaching the operating hours, a connected indicator lamp
blinks continuously until the counter is reset.
176
In this service routine, the total operating hours can be read out according to the procedure
example described below for parameter 177.
177
Display of operating hours since the last service.
Display example of operating hours or hours since the last service and operating hours counter reset.
Display on the control:
Select parameter 177.
Press the E key
Sr7
Press the >> key
h t
(hours /thousands letter symbol)
Press the E key
000
hours /thousands display)
Press the E key
h h
(hours / hundreds letter symbol)
Press the E key
000
(hours / hundreds display)
Press the E key
Min
(minutes letter symbol)
Press the E key
00
(minutes display)
Press the E key
Sec
(seconds letter symbol)
Press the E key
00
(seconds display)
Press the E key
MS
(milliseconds letter symbol)