Instruction manual

Instruction Manual
- 22 -
Press the E key
000
(milliseconds display)
Press the E key
rES
see chapter "Set and Reset Operating Hours Counter"
Press the E key
The process will be repeated from the hours display.
Press the P key twice
e. g. 400
(sewing process can be started)
Display on the V810 control panel:
Select parameter 177.
Press the E key
Sr7 [°]
Press the >> key
hoUr
(hours letter symbol)
Press the E key
000000
(hours display)
Press the E key
Min
(minutes letter symbol)
Press the E key
00
(minutes display)
Press the E key
SEc
(seconds letter symbol)
Press the E key
00
(seconds display)
Press the E key
MSEc
(milliseconds letter symbol)
Press the E key
000
(milliseconds display)
Press the E key
rES F2
see chapter "Set and Reset Operating Hours Counter"
Press the E key
The process will be repeated from the hours display.
Press the P key twice
e. g. DA321G
(sewing process can be started)
Display on the V820/V850 control panel:
Select parameter 177.
Press the E key
F-177
Sr7 [°]
Press the >> key
hoUr
000000
(hours display)
Press the E key
Min
00
(minutes display)
Press the E key
Sec
00
(seconds display)
Press the E key
MSEc
000
(milliseconds display)
Press the E key
rES
F2
see chapter "Set and Reset Operating
Hours Counter"
Press the P key twice
e. g. 3500
DA321G
(sewing process can be started)
5.15.1 Set and Reset Operating Hours Counter
The number of hours has been reached (service necessary):
Press the >> key or F2 once
The operating hours counter is set to "0" and restarted.
The number of hours has not yet been reached:
Press the >> or F2 key 3 times
The operating hours counter is set also to "0" and
restarted.
A value in parameter 177 has been changed:
After displaying rES ..., when the E key is pressed again, SEt will then be displayed.
If the changed value is to be saved, press the >> or F2 key 3 times.
5.15.2 Total Operating Hours Display
In this service routine enabled using parameter 176, the total number of operating hours is displayed.
The sequence of displayed values is as with parameter 177.
The values can only be displayed, not varied. Therefore, letter symbols "rES" for "reset" and "SEt" for "set" will
not appear.