6.4.6  Backtack Synchronization 
Function with or without control panel 
Parameter 
Backtack synchronization for the end backtack on/off 
Backtack synchronization speed 
(nSo) 
(nrS) 
123 
124 
If parameter 123 is on, the backtack speed will be switched to backtack synchronization speed one stitch before 
engaging and disengaging of the backtack solenoid. The backtack speed is released at the next position 2. If 
the synchronization speed that can be set by means of parameter 124 is higher than the backtack speed, the 
latter is maintained. Backtack synchronization applies only for the end backtack. 
6.5  Start ornamental backtack 
Function without control panel 
Control 
Single start ornamental backtack 
Double start ornamental backtack 
Start ornamental backtack Off  
Segment 1 on 
Segment 2 on 
Both segments off 
key E (S2) 
Function with control panel 
V810/V820/V850 
Single start ornamental backtack 
Double start ornamental backtack 
Start ornamental backtack Off  
left-hand arrow above key On 
right-hand arrow above key On 
both arrows Off 
Key 1 
Function with or without control panel 
Parameter 
Ornamental backtack stitch count forwards 
Ornamental backtack stitch count backwards 
Start backtacking speed 
Function "ornamental backtack" On/Off 
Start delay after disabling the sewing foot lifting signal 
Ornamental backtack stop time 
Last selected forward section on start ornamental backtack on/off 
(SAv) 
(SAr) 
(n3) 
(SrS) 
(t3) 
(tSr) 
(Zrv) 
080 
081 
112 
135 
202 
210 
215 
The abbreviations set in parentheses ( ) are only visible if a V820/V850 control panel is connected! 
Difference from the standard start backtack: 
  The drive stops for stitch regulator switching 
  The stop time can be set 
  After the backwards section of the backtack, there is another forwards backtack section with the same stitch 
count as the previous backward section, corresponding to the setting of parameter 215. 
  The stitch count of the ornamental backtack can be set with separate parameters. 
Parameter 137 can be used to select the stitch length (normal or long stitch) during the backtack. The display 
does not light up during the backtack. 
137 = 0 
The backtack is executed with a long stitch length. 
137 = 1 
The backtack is executed with a normal stitch length. 
When using the V820/V850 control panel, direct access by means of the function key (key 9) is possible. 
Function with control panel 
Parameter 
Ornamental backtack On/Off 
(-F-) 
008 = 2 