Instruction manual
Instruction Manual 
- 36 - 
Resetting the stitch counter (A, B, or C) 
Short actuation of the key (<1 sec.) sets the currently selected stitch counter to the value selected with the 
parameters 086, 087, or 088. 
Sequence with thread monitor function turned on 
During sewing, the counter value is decremented with each stitch, and the remaining number of stitches 
displayed. 
Once the end of the countdown is reached, the V810 indicates the left bobbin with the C symbol or D for the 
right bobbin. On the V820/V850, the end of the countdown is indicated by flashing of the symbols for the left 
and/or right bobbins on the display instead of the model designation. In addition, the LEDs provided for this 
function on the machine flash (flash frequency 4 Hz). 
The drive stops. 
Automatically sequenced seam sections such as seams with stitch counting or light barrier seams will be 
interrupted, except for the start and end backtacks. After the pedal is in the 0 position and a subsequent 
forwards actuation, the seam can be continued. 
It is necessary to adjust the number of stitches in such a way that the bobbin content is not completely 
exhausted by the end of the count.  
After replacing the bobbin, a short press on the key indicated above will reset the thread monitor counter to the 
starting value. 
The counter value remains stored after power--off and continues the the thread monitor count after power is 
restored.- 
On the display of the controller, there is no display for the thread monitor. 
6.16  Needle cooling / undercutter 
Function with or without control panel 
Parameter 
Needle cooling On/Off 
Switching speed for needle cooling on/off 
Power-off delay of needle cooling after stop 
Needle cooling / undercutter function 
(nk) 
(nnk) 
(dnk) 
(Fnk) 
095 
120 
183 
185 
Parameter 185 can be used to program the function of the needle cooling / undercutter output. 
185 = 1 
Needle cooling is turned on during the entire sewing process. The power-fulfillment can be 
delayed after the stop (parameter 183). 
185 = 2 
The undercutter output is turned on when the pedal is pushed forward. 
185 = 3 
Needle cooling is turned off depending on the speed. The switching speed provided for this can be 
adjusted with parameter 120. 
When using the V820/V850 control panel, direct access by means of the function key (key 9) is possible. 
Function with control panel 
Parameter 
Needle cooling On/Off 
(-F-) 
008 = 4 
6.17  Function modules for outputs A / B / C 
The function modules A / B / C are used for the flexible programming of function sequences. 
The modules are each assigned one input, one output, and one LED. A signal on the inputs to the module 
influences, in addition to the reaction to the outputs assigned to them according to the table, things including the 
seam sequence, backtack, and speed limitation. 
  Module 
A  
B 
C 
Input / socket 
in4 / A/8 
in1 / A/7 
in7 / A/9 
Output / socket 
M6 / A/30 
M16 / A/20 
M30 / A/15 
LED (Output) / socket 
M10 / A/29 
M11 / A/31 
M18 / A/22 
6.17.1  Function module A - no function 
  Parameter 250 = 0, function module for output A is turned off. 










