Instruction manual

Instruction Manual
- 50 -
6.25 Seam with Stitch Counting
Function without control panel
Parameter
Stitch counting On/Off
(StS)
015
Function with control panel
V820/V850
Stitch counting forwards On
Stitch counting backwards On
Stitch counting Off
Left arrow on
Right arrow on
both arrows Off
Key 2
6.25.1 Stitches for stitch counting
Function with or without control panel
Parameter
Number of stitches for the seam with stitch counting
(Stc)
007
The stitches for stitch counting can be programmed and varied using the above parameters directly on the
control or on a connected V810/V820/V850 control panel.
For fast operator information (HIT) when using the V820/V850 control panel, the value of the function switched
on using key 2 can be displayed for approx. 3 seconds. During this time, the value can be varied directly by
pressing key + or -.
6.25.2 Stitch Counting Speed
Function with or without control panel
Parameter
Stitch Counting Speed
Speed mode for a seam with stitch counting
(n12)
(SGn)
118
141
A certain speed behavior for the stitch counting can be selected using parameter141.
141 = 0
Countdown at speed controlled by the pedal
141 = 1
Execution at fixed speed n12, when pressing the pedal forward (position >1)
141 = 2
Execution at limited speed n12, when pressing the pedal forward (position >1)
141 = 3
Automatic execution at fixed speed after having pressed the pedal once.
The procedure can be interrupted by "heelback (-2)"
141 = 4
Automatic execution at fixed speed n1 after having pressed the pedal once.
The procedure can be interrupted by "heelback (-2)"
The sewing speed is reduced in each stitch depending on the actual speed (max. 11 stitches before the end of
stitch counting), in order to be able to stop exactly at the end of counting. When the light barrier is on, free
sewing will be performed after stitch counting.
6.25.3 Seam with Stitch Counting When Light Barrier Is On
Function with or without control panel
Parameter
Light barrier On/Off
Stitch counting On/Off
(LS)
(StS)
009
015
Function with control panel
V820/V850
Light barrier On/Off
Stitch counting On/Off
Key 3
Key 2
When "stitch counting and light barrier function" is set, the number of stitches will be executed first, then the light
barrier will be activated.