Instruction manual

- DA321G5321
- 51 -
6.26 Plugging
Function with control panel
V820/V850
parameter
Seam end in plug program execution
(dkn)
322 = 3
The plugging function is only possible after seam programming (teach-in).
Two seams are programmed, one forwards and one backwards.
The end of the plugging process takes place after the pedal returns after starting the thread trimming process.
6.27 Free Seam and Seam with Light Barrier
Function with or without control panel
Parameter
Positioning speed
Upper limit of maximum speed
Limited speed according to setting of parameter 142
Lower limit of maximum speed
Speed mode free seam
(n1)
(n2)
(n12)
(n2_)
(SFn)
110
111
118
121
142
Speed control for the free seam and the seam with light barrier can be selected with parameter 142.
142 = 0
Countdown at speed controlled by the pedal
142 = 1
Execution at fixed speed n12, when pressing the pedal forward (position >1)
142 = 2
Execution at limited speed n12, when pressing the pedal forward (position >1)
142 = 3
Only for the seam with light barrier:
- Automatic execution at fixed speed after having pressed the pedal once.
- The seam end is initiated by light barrier.
- The procedure can be interrupted by heelback (-2).
- If the light barrier is not on, speed as with parameter setting 142 = 0.
When using a control panel, the maximum speed is displayed after power on and thread trimming and can be
varied directly using the +/- keys on the control panel. The setting range lies between the values of parameters
111 and 121.
6.28 Light barrier
The light barrier module LSM002 is provided as the light barrier, and is connected to socket B18.
Furthermore, an external light barrier can be connected to socket A/13.
Both light barrier inputs trigger the same function and can be turned on and/or off with the same
parameters.
Function with or without control panel
Parameter
Light barrier On/Off
009
Function with control panel
V820/V850
Light barrier covered/uncovered On
Light barrier uncovered/covered On
Light barrier Off
Right arrow on
Left arrow on
both arrows Off
Key 3
6.28.1 Speed after Light Barrier Sensing
Function with or without control panel
Parameter
Speed after Light Barrier Sensing
(n5)
114