16  Intermediate backtack / intermediate stitch condensing: 
Upon pressing the key, the backtack or stitch condensing will be enabled anywhere in the seam and at 
standstill of the drive. 
17  Stitch Regulator Suppression/Recall: 
Upon pressing the key, the backtack or stitch condensing operation will be suppressed or recalled once.  
18  Thread tension reduction 
19  Reset bobbin thread monitor: 
After inserting a full bobbin, the stitch counter is set to the configured value when the key is pressed. 
(Parameter 195=4) 
20  Handwheel running in the direction of rotation: 
When the key is pressed, the drive runs (Parameter 161=0). 
21  Handwheel running in the direction of rotation: 
When the key is pressed, the drive runs in the opposite direction (Parameter 161). 
22  Switch stitch length 
23  Transport roller 
24  No function 
25  DB2000: 
When the key is pressed, the drive runs with a fixed speed n10 (DB2000) 
26  Input of speed limitation n11 (DB3000) 
27  Input of speed limitation n10 (DB2000) 
28  External light barrier: 
 In this mode it is possible to initiate the seam end using a key, not the light barrier. But the light barrier 
function must be On.  
29  Single stitch with stitch length switching 
30  Emergency stop: 
After the key is pressed, the drive stops in position 2. The sewing foot is lifted. On the V820/V850, the run 
block symbol flashes; on the V810 "Stop" flashes. The drive functions are blocked. Only after power-off/on 
is the drive again ready to use. 
31...38  No function 
39  Switch to the next pattern in TEACH IN: 
 Upon pressing the key, the program switches to the next pattern. 
40  Switch back to the previous pattern TEACH IN: 
 Upon pressing the key, the program switches to the previous pattern. 
41...45  No function 
46  Key for function module A 
47  Key for function module B 
48  Signal A1 is issued: 
 Upon pressing the key, signal A1 is issued immediately. 
49  Signal A1 switchable as flip-flop: 
Upon pressing the key, signal A1 is activated and deactivated when pressing the key again. 
50  No function 
51  Signal A2 is issued: 
 Upon pressing the key, signal A2 is issued immediately. 
52  Signal A2 switchable as flip-flop: 
Upon pressing the key, signal A2 is activated and deactivated when the key is pressed again. 
53  No function 
54  No function 
55  Reversal of the direction of rotation 
56  No function 
57  No function 
58  Intermediate backtack latching 
59...77  No function 
78  Switching of the high lift for walking foot function latching/keyed 
79...88  No function 