Instruction manual
Instruction Manual 
- 56 - 
6.32  Signals A1 and A2 
When using the V820/V850 control panel, direct access by means of the function key (key 9) is possible. 
Function with or without control panel 
Parameter 
Signal A1 and/or A2 On/Off with slide-in strip 1...4 
(left-hand arrow = A1, right-hand arrow = A2) 
(-F-) 
008 = 5 
Function with control panel 
V820/V850 
Signal A1 On 
Signal A2 On 
Signals A1 and A2 On 
Signals A1 and A2 Off 
Left arrow on   
Right arrow on 
Both arrows on 
Both arrows Off 
Key 8 
Parameters 300-309, 330, 331 for A1 and 310-319, 335, 336 for A2 determine when and how long the signals 
are enabled or disabled, or other conditions take effect. 
When a V820/V850 control panel is used, signals A1/A2 can be assigned to a seam using key 8 (slide-in strips 
6, 8, 9 and 10). 
Using parameter 300/310 it is possible to set which output (M1-M11 or VR) can be switched by A1/A2. 
Using parameter 301/311 it is possible to select if signal A1/A2 is effective until the seam end, stop at the seam 
end, over time or during stitch counting. 
301/311 = 0 
to end of seam (parameter 320) 
301/311 = 1 
Over time (parameter 304/305/314/315) 
301/311 = 2 
Until stop at the seam end 
301/311 = 3 
During stitch counting (parameter 308/309/318/319) 
301/311 = 4 
Puller function (parameter 309/319) 
Using parameter 302/312 it is possible to select if the signal A1/A2 shall be effective at the start of the seam, 
after light barrier sensing or at the seam end. 
302/312 = 0 
Signal at the beginning of the seam 
302/312 = 1 
Signal after light barrier sensing 
302/312 = 2 
Start of the signal when the drive stops at the seam end 
302/312 = 3 
Signal from light barrier covered at the start of the seam 
302/312 = 4 
Signal switchable only manually 
Using parameter 303/313 it is possible to select if the signals shall be activated with or without delay. 
303/313 = 0 
Without delay time 
303/313 = 1 
After a delay time (parameter 308/318) 
303/313 = 2 
After a stitch count (parameter 309/319) 
The delay time can be selected using parameter 304/314. 
The ON period can be selected using parameter 305/315. 
The speed mode can be set using parameter306/316 . The speed limitation is effective only when the signal is 
On. 
306/316 = 0 
Pedal controlled speed 
306/316 = 1 
Limitation to speed n9 (parameter 288) 
306/316 = 2 
Limitation to speed n11 (parameter 289) 
The function for A1/A2 can be enabled or disabled separately using parameter 307/317. 
Using parameter 308/318 it is possible to select if the signals shall be activated with or without delay stitch count 
308/318 = 0 
Without delay stitches 
308/318 = 1 
with delay stitches 
Separate stitch counts can be selected using parameter309/319. 
The switch-off moment can be set using parameter 320. 
320 = 0 
Signals effective until seam end 
320 = 1 
Signals effective until pedal has been pressed to pos. 0 (neutral) 