7.1.2 Outputs of control
Select parameter 173.
Select the desired output using the +/- keys.
On the V810 control panel or on the built-in keypad in the control, the >> key is used to turn on the
associated output, if it is connected and working.
On the V820 control panel, instead of the >> key the key (lower right, at the outer edge) must be pressed.
Display example for backtacking output on the V810 control
panel:
2-34 oUt vr
Display example for backtacking output on the V820 control
panel:
2-34 oUt vr
Display example for backtacking output on the V850 control
panel:
ST2/34 OUT: VR
Assignment of outputs
Display
Function / Output
on socket A (ST2)
OUT VR
Backtacking
34
OUT FL
Sewing foot lifting
35
OUT 1
M1
37
OUT 2
M2
28
OUT 3
M3
27
OUT 4
M4
36
OUT 5
M5
32
OUT 6
M6
30
OUT 7
M7
23
OUT 8
M8
24
OUT 9
M9
25
OUT 10
M10
29
OUT 11
M11
31
OUT 30
M30
15
OUT 31
M31
18
OUT 14
M14
26
OUT 16
M16
20
OUT 17
M17
21
OUT 18
M18
22
On the V810 control panel, OUT 1, for example, is displayed as M 01.