Instruction manual

- DA321G5321
- 9 -
Function
Control
Call-up of the Fast Installation Routine SIR
(Sir)
500
Setting on the V810 control panel:
Input code number 3112!
Press the E key
the lowest parameter 2.0.0. of this level appears
Select 500
Parameter 5.0.0. displayed
Press the E key
The character [o] appears and flashes
Press the >> key
Parameter 2.8.0 appears
Press the E key
Parameter value of the select resistor detected, e.g. 1000, is displayed.
+/- keys now do not work, parameter value cannot change
Press the E key
Parameter 2.9.0. appears (functional sequence "thread trimming
operations")
Press the E key
Parameter value 00 appears
Press the +/- key
Parameter value (machine model (mode) for the select resistor detected) can
be configured
Press the E key
Parameter 1.6.1. appears (Direction of motor rotation)
Press the E key
Parameter value 1 appears
Press the +/- key
The parameter value can be changed
Press the E key
Parameter 2.7.2. appears (transmission ratio)
Press the E key
Parameter value 1000 appears
Press the +/- key
The parameter value can be changed
Press the E key
Parameter 1.7.0. appears (setting the reference position)
Press the E key
The character [o] appears and flashes
Upon pressing the E key once more the program returns to parameter 2.8.0!
Press the P key twice
The system exits the SIR routine
Setting on the V820/V850 control panel:
Input code number 3112!
Press the E key
the lowest parameter 2.0.0 of this level appears
Select 500
Parameter 5.0.0 displayed
Press the E key
The character [o] appears and flashes
Press the >> key
Parameter 280 SEL 1000 appears (display of the select resistor e. g. 1000).
+/- keys now do not work, parameter value cannot change
Press the E key
Parameter 290 MkA 00 appears (machine model (mode) for the select
resistor detected)
Press the +/- key
Parameter value for mode can be set
Press the E key
Parameter 161 drE 1 appears (Direction of motor rotation)
Press the E key
Parameter value 1 appears
Press the E key
Parameter 272 trr 100 appears (transmission ratio)
Press the +/- key
The parameter value can be changed
Press the E key
Parameter 170 SR1 appears (setting the reference position). the character
[o] appears and flashes
Upon pressing the E key once more the program returns to parameter 2.8.0!
Press the P key twice