User`s guide

40
DDE Item Names In PCIS-DDE
4.10 PCI-9113
Analog Input and Range Setting Command Set
Command Item Name
Requested/Poked value
R/W Data Type
Read Analog
Input
PAI0…PAI31
Data range:
0 ~ 4095
example: 2048
R Integer
Fast Analog
Input
PASAI0 …
PASAI31*
Data range:
0 ~ 4095
example: 2048
R Integer
Analog Input
Range Setting
PSR
Data Range*:
1, 2, 7 ~ 12 (Bipolar)
15, 19 ~ 21 (Unipolar)
Example: 2, indicates that the
AI range is ±5V
W Integer
* The analog input signal polarity and full range of PCI9113 have to be set
by using the jumpers (JP1 and JP2) on board. Please refer to the
PCI-9113 user’s manual for the details.
* In PCIS-DDE, each analog input range is represented by an integer. The
valid input ranges and their corresponding integers for PCI-9113 are:
Analog Input Range Represented Integer
±10V 1
±5V 2
±0.5V 7
±0.05V 8
±0.005V 9
±1V 10
±0.1V 11
±0.01V 12
0 ~ 10V 15
0 ~ 1V 19
0 ~ 0.1V 20
0 ~ 0.01V 21
* “PASAIn” and “PAIn” (n is the channel number) commands are both used
for analog data in. For signal channel analog data input, the performance
of these two commands are almost the same. However, for
multi-channels analog data input, using “PASAIn” can get much higher